CBS 2019
CBSMD教育中心
中 文

分叉支架

Abstract

Recommended Article

PCI for obstructive bifurcation lesions the 14th consensus document from the european bifurcation club Streamlined reverse wire technique for the treatment of complex bifurcated lesions The EBC TWO Study (European Bifurcation Coronary TWO): A Randomized Comparison of Provisional T-Stenting Versus a Systematic 2 Stent Culotte Strategy in Large Caliber True Bifurcations Comparison of intravascular ultrasound-guided with angiography-guided double kissing crush stenting for patients with complex coronary bifurcation lesions: rationale and design of a prospective, randomized and multicenter DKCRUSH VIII trial Developing a Mobile Application for Global Cardiovascular Education Double-Kiss-Crush Bifurcation Stenting: Step-by-Step Troubleshooting Technical aspects of the culotte technique Incidence of Adverse Events at 3 Months Versus at 12 Months After Dual Antiplatelet Therapy Cessation in Patients Treated With Thin Stents With Unprotected Left Main or Coronary Bifurcations

Original Research2020 Jul 14;EIJ-D-20-00334.

JOURNAL:Eurointervention. Article Link

Feasibility and efficacy of the ultrashort side branch dedicated balloon in coronary bifurcation stenting

Y Murasato, M Nishihara, T Mori et al. Keywords: kissing balloon inflation vs. glider balloon; stent configuration; high-angled bifurcation; coronary bifurcation stenting

ABSTRACT

AIMS - We sought to investigate the feasibility and efficacy of the Glider balloon (GB), a side branch (SB) dedicated balloon 4-mm in length, in coronary bifurcation stenting.

METHODS AND RESULTS - In bifurcation bench models, stent configuration was examined with micro-focus computed tomography after crossover stenting followed by GB dilation or kissing balloon inflation (KBI). GB dilation maintained cross-sectional stent area without significant deformation and presented effective jailed strut removal in a high-angled bifurcation model.


We performed GB dilatation after main vessel (MV) stenting for 207 lesions in 194 patients, which included left main, true-bifurcation lesion, and two-stent treatment in 42.0%, 45.9%, and 14.0%, respectively. Proximal optimization technique (POT) or POT-like inflation was performed in 82.1%. GB crossing failure, SB stenting due to dissection, and stent deformation requiring correction by KBI or MV dilation occurred in 8.7, 1.4, and 5.8%, respectively. Finally, simple GB dilation without KBI had been completed in 91.8% for SB dilation. At 1-year follow-up, target lesion revascularization, cardiac death, myocardial infarction, and stent thrombosis were found in 7.2%, 2.1%, 2.1%, and 1.0%, respectively.


CONCLUSION - Simple GB dilation after adequate expansion of proximal MV stent provided acceptable acute and long-term results as an alternative to KBI.