CBS 2019
CBSMD教育中心
中 文

经导管主动脉瓣置换

Abstract

Recommended Article

Transcatheter Aortic-Valve Replacement with a Self-Expanding Valve in Low-Risk Patients Transcatheter Aortic-Valve Replacement with a Balloon-Expandable Valve in Low-Risk Patients Early Versus Standard Discharge After Transcatheter Aortic Valve Replacement: A Systematic Review and Meta-Analysis Surgical or Transcatheter Aortic-Valve Replacement in Intermediate-Risk Patients Preventing Coronary Obstruction During Transcatheter Aortic Valve Replacement From Computed Tomography to BASILICA Transcatheter or Surgical Aortic-Valve Replacement in Intermediate-Risk Patients Transcatheter Laceration of Aortic Leaflets to Prevent Coronary Obstruction During Transcatheter Aortic Valve Replacement: Concept to First-in-Human A prospective, randomised trial of transapical transcatheter aortic valve implantation vs. surgical aortic valve replacement in operable elderly patients with aortic stenosis: the STACCATO trial

Original ResearchVolume 74, Issue 15, October 2019

JOURNAL:J Am Coll Cardiol. Article Link

Ascending Aortic Length and Risk of Aortic Adverse Events: The Neglected Dimension

J Wu, MA Zafar, Yupeng Li, JA Elefteriades et al. Keywords: aortic adverse events; aortic aneurysm; aortic dimensions; aortic elongation; natural history; thoracic aortic aneurysm

ABSTRACT


BACKGROUND - Little information is available regarding the longitudinal changes of the aneurysmal ascending aorta.

 

OBJECTIVES - This study sought to outline the natural history of ascending thoracic aortic aneurysm (ATAA) based on ascending aortic length (AAL) and develop novel predictive tools to better aid risk stratification.

 

METHODS - The ascending aortic diameters and lengths, and long-term aortic adverse events (AAEs) (rupture, dissection, and death) of 522 ATAA patients were evaluated using comprehensive statistical approaches.

 

RESULTS - An AAL of 13 cm was associated with an almost 5-fold higher average yearly rate of AAEs compared with an AAL of <9 cm. Two AAL hinge pointswith a sharp increase in the estimated probability of AAEs were detected between 11.5 and 12.0 cm, and between 12.5 and 13.0 cm. The mean estimated annual aortic elongation rate was 0.18 cm/year, and aortic elongation was age dependent. Aortic diameter increased 18% due to dissection while AAL only increased by 2.7%. There was a noticeable improvement in the discrimination of the logistic regression model (area under the receiver-operating characteristic curve: 0.810) due to the introduction of aortic height index (AHI) (diameter height index + length height index). The AHIs <9.33, 9.38 to 10.81, 10.86 to 12.50, and 12.57 cm/m were associated with a 4%, 7%, 12%, and 18% average yearly risk of AAEs, respectively.

 

CONCLUSIONS - An aortic elongation of 11 cm serves as a potential intervention criterion for ATAA, which is even more reliable than diameter due to its relative immunity to dissection. AHI (including both length and diameter) is more powerful than any single parameter in this study.