CBS 2019
CBSMD教育中心
中 文

经导管主动脉瓣置换

Abstract

Recommended Article

Relationship Between Hospital Surgical Aortic Valve Replacement Volume and Transcatheter Aortic Valve Replacement Outcomes Aortic Valve Stenosis Treatment Disparities in the Underserved JACC Council Perspectives Comparison of safety and periprocedural complications of transfemoral aortic valve replacement under local anaesthesia: minimalist versus complete Heart Team Association of Smoking Status With Long‐Term Mortality and Health Status After Transcatheter Aortic Valve Replacement: Insights From the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry Transcatheter Aortic Valve Replacement During Pregnancy Prognostic implications of baseline 6‐min walk test performance in intermediate risk patients undergoing transcatheter aortic valve replacement Raising the Evidentiary Bar for Guideline Recommendations for TAVR: JACC Review Topic of the Week Cardiac Structural Changes After Transcatheter Aortic Valve Replacement: Systematic Review and Meta-Analysis of Cardiovascular Magnetic Resonance Studies

Original Research2020 Jul 5;S0167-5273(20)33411-2.

JOURNAL:Int J Cardiol . Article Link

Long-term outcome of prosthesis-patient mismatch after transcatheter aortic valve replacement

M Compagnone, G Marchetti, F Saia et al. Keywords: aortic valve stenosis; degenerated aortic valve bioprosthesis; prosthesis-patient mismatch; TAVR

ABSTRACT


BACKGROUND - Incidence and long-term clinical consequences of prosthesis-patient mismatch (PPM) after transcatheter aortic valve replacement (TAVR) are still unclear.


METHODS - We enrolled 710 consecutive patients who underwent TAVR. PPM was defined as absent if the index orifice area (iEOA) was >0.85 cm2/m2, moderate if the iEOA was between 0.65 and 0.85 cm2/m2 or severe if the iEOA was <0.65 cm2/m2.

RESULTS - Among the 566 patients fulfilling the study criteria, the distribution of PPM was as follows: 50.5% none ( n = 286), 43% moderate PPM ( n = 243) and 6.5% severe PPM ( n = 37). At 5-year follow-up, patients with severe PPM had a significantly higher incidence of the combined endpoint of cardiovascular death, acute myocardial infarction and stroke ( p = .025) compared with the other patients. After adjusting the results for possible confounders, severe PPM remained an independent predictor of long-term adverse outcome (HR: 2.46; 95% Confidence Interval: 1.10–5.53). The independent predictors of severe PPM were valve-in-valve procedure and body mass index. Balloon-expandable valves were not associated with higher rates of severe PPM in comparison with self-expandable valves (5% vs. 8%, respectively, p = .245).


CONCLUSIONS -In our study severe PPM emerged as a risk factor for long-term major adverse cardiac and cerebrovascular events.