CBS 2019
CBSMD教育中心
中 文

经导管主动脉瓣置换

Abstract

Recommended Article

Short Length of Stay After Elective Transfemoral Transcatheter Aortic Valve Replacement Is Not Associated With Increased Early or Late Readmission Risk Clinical impact of conduction disturbances in transcatheter aortic valve replacement recipients: a systematic review and meta-analysis Decline in Left Ventricular Ejection Fraction During Follow-Up in Patients With Severe Aortic Stenosis Randomized Evaluation of TriGuard 3 Cerebral Embolic Protection After Transcatheter Aortic Valve Replacement: REFLECT II Single Versus Dual Antiplatelet Therapy Following TAVR: A Systematic Review and Meta-Analysis of Randomized Controlled Trials Anticoagulation After Surgical or Transcatheter Bioprosthetic Aortic Valve Replacement Anticoagulation with or without Clopidogrel after Transcatheter Aortic-Valve Implantation Left Ventricular Rapid Pacing Via the Valve Delivery Guidewire in Transcatheter Aortic Valve Replacement

Review ArticleSeptember 9, 2020

JOURNAL:JAMA Cardiol. Article Link

Considerations for Optimal Device Selection in Transcatheter Aortic Valve Replacement: A Review

BE Claessen, GHL Tang, AS Kini et al. Keywords: TAVR; device selection; RCT

ABSTRACT

IMPORTANCE - Aortic valve stenosis (AS) is the most common manifestation of acquired valvular heart disease in developed countries. Several large-scale randomized clinical trials investigating the entire spectrum of patients with severe symptomatic AS from low to prohibitive risk have established transcatheter aortic valve replacement (TAVR) as a safe and effective alternative to surgical aortic valve replacement.


OBSERVATIONS - There are currently only 3 types of TAVR devices commercially available in the US, but several other valve types are undergoing clinical trials in the US. Because of fundamental differences in engineering features, each TAVR device type has specific strengths and limitations. This review aims to provide an overview of design features and clinical outcomes of various TAVR devices that are either commercially available or undergoing clinical investigation.


CONCLUSIONS AND RELEVANCE - Given the lack of large-scale head-to-head comparisons of various TAVR devices and the rapid development of new device iterations, there is insufficient evidence to claim superiority of one device type over another. Nonetheless, as each TAVR device has unique design characteristics, certain patient-related and anatomy-related factors may slightly favor one or several particular designs.