Transcatheter Aortic Valve Replacement

Abstract

Recommended Article

Edoxaban versus Vitamin K Antagonist for Atrial Fibrillation after TAVR 2020 ACC Expert Consensus Decision Pathway on Management of Conduction Disturbances in Patients Undergoing Transcatheter Aortic Valve Replacement A Report of the American College of Cardiology Solution Set Oversight Committee Health Status After Transcatheter Versus Surgical Aortic Valve Replacement in Low-Risk Patients With Aortic Stenosis Computed tomography angiography-derived extracellular volume fraction predicts early recovery of left ventricular systolic function after transcatheter aortic valve replacement Thrombotic Versus Bleeding Risk After Transcatheter Aortic Valve Replacement: JACC Review Topic of the Week Randomized Evaluation of TriGuard 3 Cerebral Embolic Protection After Transcatheter Aortic Valve Replacement: REFLECT II Cardiovascular Magnetic Resonance as a complementary method to Transthoracic Echocardiography for Aortic Valve Area Estimation in patients with Aortic Stenosis: A systematic review and meta-analysis Anticoagulation with or without Clopidogrel after Transcatheter Aortic-Valve Implantation

Original ResearchVolume 13, Issue 6, March 2020

JOURNAL:JACC Cardiovasc Interv. Article Link

Coronary Protection to Prevent Coronary Obstruction During TAVR: A Multicenter International Registry

T Palmerini, T Chakravarty, F Saia et al. Keywords: coronary obstruction; stent thrombosis; TAVR

ABSTRACT


OBJECTIVES - The aim of this study was to investigate the safety and efficacy of coronary protection by preventive coronary wiring and stenting across the coronary ostia in patients at high risk for coronary obstruction after transcatheter aortic valve replacement (TAVR).

 

BACKGROUND - Coronary obstruction following TAVR is a life-threatening complication with high procedural and short-term mortality.

 

METHODS - Data were collected retrospectively from a multicenter international registry between April 2011 and February 2019.

 

RESULTS - Among 236 patients undergoing coronary protection with preventive coronary wiring, 143 had eventually stents implanted across the coronary ostia after valve deployment. At 3-year follow-up, rates of cardiac death were 7.8% in patients receiving stents and 15.7% in those not receiving stents (adjusted hazard ratio: 0.42; 95% confidence interval: 0.14 to 1.28; p = 0.13). There were 2 definite stent thromboses (0.9%) in patients receiving stents, both occurring after TAVR in “valve-in-valve” procedures. In patients not receiving stents, there were 4 delayed coronary occlusions (DCOs) (4.3%), occurring from 5 min to 6 h after wire removal. Three cases occurred in valve-in-valve procedures and 1 in a native aortic valve procedure. Distance between the virtual transcatheter valve and the protected coronary ostia <4 mm was present in 75.0% of patients with DCO compared with 30.4% of patients without DCO (p = 0.19).

 

CONCLUSIONS - In patients undergoing TAVR at high risk for coronary obstruction, preventive stent implantation across the coronary ostia is associated with good mid-term survival rates and low rates of stent thrombosis. Patients undergoing coronary protection with wire only have a considerable risk for DCO.