CBS 2019
CBSMD教育中心
中 文

Transcatheter Aortic Valve Replacement

Abstract

Recommended Article

Single Versus Dual Antiplatelet Therapy Following TAVR: A Systematic Review and Meta-Analysis of Randomized Controlled Trials Comparison of 1-Year Pre- And Post-Transcatheter Aortic Valve Replacement Hospitalization Rates: A Population-Based Cohort Study Bioprosthetic valve oversizing is associated with increased risk of valve thrombosis following TAVR Rationale and design of a randomized clinical trial comparing safety and efficacy of Myval transcatheter heart valve versus contemporary transcatheter heart valves in patients with severe symptomatic aortic valve stenosis: the LANDMARK trial Extracellular Myocardial Volume in Patients With Aortic Stenosis Relationship between B-type natriuretic peptide and invasive haemodynamics in patients with severe aortic valve stenosis Temporal Trends in Transcatheter Aortic Valve Replacement in France: FRANCE 2 to FRANCE TAVI Transcatheter Versus Surgical Aortic Valve Replacement in Low-Risk Patients

Original ResearchVolume 13, Issue 9, May 2020

JOURNAL:JACC: Cardiovascular Interventions Article Link

Transcatheter Aortic Valve Replacement in Low-Risk Patients With Symptomatic Severe Bicuspid Aortic Valve Stenosis

R Waksman, PE Craig, R Torguson et al. Keywords: aortic stenosis; bicuspid aortic valve; low risk; transcatheter aortic valve replacement

ABSTRACT

OBJECTIVES - The aim of this study was to evaluate clinical outcomes and transcatheter heart valve hemodynamic parameters after transcatheter aortic valve replacement (TAVR) in low-risk patients with bicuspid aortic stenosis (AS).

 

BACKGROUND - TAVR is approved for low-risk patients in the United States. However, patients with bicuspid AS were excluded from the randomized cohorts of the pivotal low-risk trials.

 

METHODS - The LRT (Low Risk TAVR) trial was an investigator-initiated, prospective, multicenter study and was the first and only U.S. Food and Drug Administrationapproved investigational device exemption trial to evaluate the feasibility of TAVR with either balloon-expandable or self-expanding valves in low-risk patients with bicuspid AS. The primary endpoint was all-cause mortality at 30 days. Baseline and follow-up echocardiography and computed tomography to detect leaflet thickening were analyzed in an independent core laboratory.

 

RESULTS - Sixty-one low-risk patients with symptomatic, severe AS and bicuspid aortic valves (78.3% Sievers type 1 morphology) underwent TAVR at 6 centers from 2016 to 2019. The mean age was 68.6 years, and 42.6% were men. At 30 days, there was zero mortality and no disabling strokes. The rate of new permanent pacemaker implantation was 13.1%; just 1 patient had a moderate paravalvular leak at 30 days. Hypoattenuated leaflet thickening was observed in 10% of patients at 30 days.

 

CONCLUSIONS - TAVR appears to be safe in patients with bicuspid AS, with short length of hospital stay, zero mortality, and no disabling strokes at 30 days. Subclinical leaflet thrombosis was observed in a minority of patients at 30 days but did not appear to be associated with clinical events.