CBS 2019
CBSMD教育中心
中 文

Transcatheter Aortic Valve Replacement

Abstract

Recommended Article

Outcomes of procedural complications in transfemoral transcatheter aortic valve replacement Guideline Update on Indications for Transcatheter Aortic Valve Implantation Based on the 2020 American College of Cardiology/American Heart Association Guidelines for Management of Valvular Heart Disease Management of Asymptomatic Severe Aortic Stenosis: Evolving Concepts in Timing of Valve Replacement Considerations for Optimal Device Selection in Transcatheter Aortic Valve Replacement: A Review Cardiac surgery following transcatheter aortic valve replacement Early Surgery or Conservative Care for Asymptomatic Aortic Stenosis Balloon-Expandable Versus Self-Expanding Transcatheter Aortic Valve Replacement: A Propensity-Matched Comparison From the FRANCE-TAVI Registry Transcatheter Aortic Valve Implantation Represents an Anti-Inflammatory Therapy Via Reduction of Shear Stress-Induced, Piezo-1-Mediated Monocyte Activation

Review ArticleSeptember 9, 2020

JOURNAL:JAMA Cardiol. Article Link

Considerations for Optimal Device Selection in Transcatheter Aortic Valve Replacement: A Review

BE Claessen, GHL Tang, AS Kini et al. Keywords: TAVR; device selection; RCT

ABSTRACT

IMPORTANCE - Aortic valve stenosis (AS) is the most common manifestation of acquired valvular heart disease in developed countries. Several large-scale randomized clinical trials investigating the entire spectrum of patients with severe symptomatic AS from low to prohibitive risk have established transcatheter aortic valve replacement (TAVR) as a safe and effective alternative to surgical aortic valve replacement.


OBSERVATIONS - There are currently only 3 types of TAVR devices commercially available in the US, but several other valve types are undergoing clinical trials in the US. Because of fundamental differences in engineering features, each TAVR device type has specific strengths and limitations. This review aims to provide an overview of design features and clinical outcomes of various TAVR devices that are either commercially available or undergoing clinical investigation.


CONCLUSIONS AND RELEVANCE - Given the lack of large-scale head-to-head comparisons of various TAVR devices and the rapid development of new device iterations, there is insufficient evidence to claim superiority of one device type over another. Nonetheless, as each TAVR device has unique design characteristics, certain patient-related and anatomy-related factors may slightly favor one or several particular designs.