The relationship between attenuated plaque identified by intravascular ultrasound and no-reflow after stenting in acute myocardial infarction: the HORIZONS-AMI (Harmonizing Outcomes With Revascularization and Stents in Acute Myocardial Infarction) trial Intravascular ultrasound-guided vs angiography-guided drug-eluting stent implantation in complex coronary lesions: Meta-analysis of randomized trials Differential prognostic effect of intravascular ultrasound use according to implanted stent length Impact of intravascular ultrasound guidance on long-term mortality in stenting for unprotected left main coronary artery stenosis Intravascular ultrasound assessment of the effects of rotational atherectomy in calcified coronary artery lesions Impact of final stent dimensions on long-term results following sirolimus-eluting stent implantation: serial intravascular ultrasound analysis from the sirius trial A three-vessel virtual histology intravascular ultrasound analysis of frequency and distribution of thin-cap fibroatheromas in patients with acute coronary syndrome or stable angina pectoris Comprehensive intravascular ultrasound assessment of stent area and its impact on restenosis and adverse cardiac events in 403 patients with unprotected left main disease Impact of post-intervention minimal stent area on 9-month follow-up patency of paclitaxel-eluting stents: an integrated intravascular ultrasound analysis from the TAXUS IV, V, and VI and TAXUS ATLAS Workhorse, Long Lesion, and Direct Stent Trials Effects of Intravascular Ultrasound-Guided Versus Angiography-Guided New-Generation Drug-Eluting Stent Implantation: Meta-Analysis With Individual Patient-Level Data From 2,345 Randomized Patients

Original Research2013 May 15;111(10):1408-14.

JOURNAL:Am J Cardiol. Article Link

Intravascular ultrasound predictors for edge restenosis after newer generation drug-eluting stent implantation

Kang SJ, Cho YR, Park GM et al. Keywords: IVUS; edge stenosis; DES

ABSTRACT


The aim of the present study was to assess the intravascular ultrasound predictors for angiographic edge restenosis after newer generation drug-eluting stent implantation. A total of 820 patients (987 lesions) who underwent newer generation drug-eluting stent placement (236 Endeavor zotarolimus-eluting stents, 246 Resolute zotarolimus-eluting stents, and 505 everolimus-eluting stents) with 9 months of angiographic surveillance were enrolled. The post-stenting angiographic and intravascular ultrasound images of 1,668 reference segments (681 proximal and 987 distal) were analyzed. Overall, 37% of angiographically normal proximal reference segments and 21% of angiographically normal distal reference segments had plaque burden >50%. In the overall cohort of 1,668 reference segments, 47 (2.8%) had 9-month angiographic edge restenosis (diameter stenosis >50%). Edge restenosis was predicted by a post-stenting reference segment plaque burden >54.5% (sensitivity 81%, specificity 80%) and a reference segment minimum lumen area of 5.7 mm(2) (sensitivity 72%, specificity 59%). The edge restenosis rate was 2.1% in the Endeavor zotarolimus-eluting stents, 2.4% in the Resolute zotarolimus-eluting stents, and 3.4% in the everolimus-eluting stents lesions (p = 0.311). The predictive cutoff of the reference plaque burden was 56.3% for Endeavor zotarolimus-eluting stents, 57.3% for Resolute zotarolimus-eluting stents, and 54.2% for everolimus-eluting stents. The criteria for residual plaque burden were similar between proximal and distal reference segments (56.4% vs 51.9%, respectively), but the minimum lumen area criteria were quite different (<7.1 mm(2) for proximal vs <4.8 mm(2) for distal reference segments). In conclusion, after newer drug-eluting stent implantation, edge restenosis was predicted by post-stenting reference segment plaque burden >55%.