CBS 2019
CBSMD教育中心
English

IVUS Guidance

科研文章

荐读文献

Impact of the Use of Intravascular Imaging on Patients Who Underwent Orbital Atherectomy Usefulness of intravascular ultrasound to predict outcomes in short-length lesions treated with drug-eluting stents American College of Cardiology Clinical Expert Consensus Document on Standards for Acquisition, Measurement and Reporting of Intravascular Ultrasound Studies (IVUS). A report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents Comparison of intravascular ultrasound guided versus angiography guided drug eluting stent implantation: a systematic review and meta-analysis First-in-man evaluation of intravascular optical frequency domain imaging (OFDI) of Terumo: a comparison with intravascular ultrasound and quantitative coronary angiography Incidence and Clinical Outcomes of Stent Fractures on the Basis of 6,555 Patients and 16,482 Drug-Eluting Stents From 4 Centers Atherosclerotic plaque with ultrasonic attenuation affects coronary reflow and infarct size in patients with acute coronary syndrome: an intravascular ultrasound study Intracoronary stenting without anticoagulation accomplished with intravascular ultrasound guidance Intravascular ultrasound-guided implantation of drug-eluting stents to improve outcome: a meta-analysis Usefulness of minimum stent cross sectional area as a predictor of angiographic restenosis after primary percutaneous coronary intervention in acute myocardial infarction (from the HORIZONS-AMI Trial IVUS substudy)

Clinical Trial2017 Jan;89(1):13-24.

JOURNAL:Catheter Cardiovasc Interv. Article Link

Long-term outcomes following mini-crush versus culotte stenting for the treatment of unprotected left main disease: insights from the Milan and New-Tokyo (MITO) registry

Kawamoto H, Takagi K, Colombo A et al. Keywords: bifurcation lesions; drug-eluting stent; percutaneous coronary intervention; unprotected left main coronary artery

ABSTRACT


OBJECTIVES - This study aimed to investigate the long-term outcomes following mini-crush versus culotte stenting with drug-eluting stents (DES) for the treatment of unprotected left main coronary artery (LMCA) disease.


BACKGROUND - Both mini-crush and culotte stenting are considered efficacious treatment options when a planned 2-stent strategy is deemed necessary for unprotected LMCA disease. However, there are limited data available with regard to the long-term clinical outcomes of each strategy in this setting.

METHODS - Between July 2002 and November 2013, 225 patients were identified. 135 patients were treated with the mini-crush technique, and 90 patients with culotte stenting. The median follow-up period was 1,263 (IQR 820-1,847) days.

RESULTS - The mini-crush group had worse lesion and procedural characteristics when compared to the culotte group. There were no significant differences in major adverse cardiac events (MACE) at 5 years (mini-crush 36.0% vs. culotte 41.4%, P = 0.57). Myocardial infarction (MI) and definite stent thrombosis (ST) occurred significantly higher (MI; 0 vs. 11.3%, log-rank P = 0.003, and definite ST; 0 vs. 6.3%, log-rank P = 0.02, respectively) in the culotte group. Cox regression analysis indicated that full stent coverage of the LMCA and SYNTAX score were independent predictors for MACE.

CONCLUSIONS - The incidence of MACE and overall TLR were comparable between groups. However, the rates of MI and definite ST were significantly higher in the culotte group. Full stent coverage of the LMCA may reduce the incidence of MACE when a two-stent strategy is used for the treatment of unprotected LMCA disease. © 2016 Wiley Periodicals, Inc.

© 2016 Wiley Periodicals, Inc.