CBS 2019
CBSMD教育中心
English

IVUS Guidance

科研文章

荐读文献

Impact of intravascular ultrasound guidance in routine percutaneous coronary intervention for conventional lesions: data from the EXCELLENT trial Consensus from the 5th European Bifurcation Club meeting Comparison of paclitaxel-eluting stents (Taxus) and everolimus-eluting stents (Xience) in left main coronary artery disease with 3 years follow-up (from the ESTROFA-LM registry) Impact of Intravascular Ultrasound-Guided Percutaneous Coronary Intervention on Long-Term Clinical Outcomes in Patients Undergoing Complex Procedures Intravascular ultrasound-derived minimal lumen area criteria for functionally significant left main coronary artery stenosis Intravascular Ultrasound Parameters Associated With Stent Thrombosis After Drug-Eluting Stent Deployment Defining a new standard for IVUS optimized drug eluting stent implantation: the PRAVIO study Contribution of stent underexpansion to recurrence after sirolimus-eluting stent implantation for in-stent restenosis Intravascular Ultrasound-Derived Virtual Fractional Flow Reserve for the Assessment of Myocardial Ischemia Comparison of inhospital mortality, length of hospitalization, costs, and vascular complications of percutaneous coronary interventions guided by ultrasound versus angiography

Clinical Trial2015 Apr;10(12):1409-17.

JOURNAL:EuroIntervention. Article Link

Angiographic and clinical comparisons of intravascular ultrasound- versus angiography-guided drug-eluting stent implantation for patients with chronic total occlusion lesions: two-year results from a randomised AIR-CTO study

Tian NL, Gami SK, Chen SL et al. Keywords: intravascular ultrasound; chronic total occlusion; late lumen loss ; minimal lumen diameter; minimal stent cross-section area

ABSTRACT



AIMS - This study sought to compare angiographic endpoints at one-year follow-up after a drug-eluting stent implantation guided by either intravascular ultrasound (IVUS) or angiography in patients with chronic total occlusion (CTO) lesions.


METHODS AND RESULTS - Patients with at least one CTO lesion recanalised successfully were randomly assigned to the IVUS-guided or the angiography-guided group. The use of IVUS for penetration of the true lumen and optimisation of stent expansion was only done in the IVUS-guided group. The primary endpoint was in-stent late lumen loss (LLL) at one-year follow-up. A total of 230 patients with CTO lesions after successful recanalisation were enrolled and followed with office visits or telephone contact up to 24 months. In-stent LLL in the IVUS-guided group was significantly lower compared to the angiography-guided group at one-year follow-up (0.28±0.48 mm vs. 0.46±0.68 mm, p=0.025), with a significant difference in restenosis of the "in-true-lumen" stent between the two groups (3.9% vs.13.7%, p=0.021). The minimal lumen diameter and minimal stent cross-section area significantly and negatively correlated with LLL (all p<0.001). The rates of adverse clinical events were comparable between the IVUS- and angiography-guided groups at two-year follow-up (21.7% vs. 25.2%, p=0.641).


CONCLUSIONS - The IVUS-guided stenting of the CTO lesion was associated with less LLL and a lower incidence of "in-true-lumen" stent restenosis. Additional study is required to identify the clinical benefit of the IVUS-guided procedure for CTO lesions. [ChiCTR-TRC-10000996].