荐读文献

Intravascular ultrasound predictors for edge restenosis after newer generation drug-eluting stent implantation Intravascular ultrasound-guided vs angiography-guided drug-eluting stent implantation in complex coronary lesions: Meta-analysis of randomized trials Mechanical complications of everolimus-eluting stents associated with adverse events: an intravascular ultrasound study Impact of final stent dimensions on long-term results following sirolimus-eluting stent implantation: serial intravascular ultrasound analysis from the sirius trial Effects of Intravascular Ultrasound-Guided Versus Angiography-Guided New-Generation Drug-Eluting Stent Implantation: Meta-Analysis With Individual Patient-Level Data From 2,345 Randomized Patients Differential prognostic effect of intravascular ultrasound use according to implanted stent length A three-vessel virtual histology intravascular ultrasound analysis of frequency and distribution of thin-cap fibroatheromas in patients with acute coronary syndrome or stable angina pectoris Impact of intravascular ultrasound guidance in routine percutaneous coronary intervention for conventional lesions: data from the EXCELLENT trial Comparison of intravascular ultrasound versus angiography-guided drug-eluting stent implantation: a meta-analysis of one randomised trial and ten observational studies involving 19,619 patients Impact of intravascular ultrasound guidance on long-term mortality in stenting for unprotected left main coronary artery stenosis

Review Article2013 Dec 5;170(1):54-63.

JOURNAL:Int J Cardiol. Article Link

Use of IVUS guided coronary stenting with drug eluting stent: a systematic review and meta-analysis of randomized controlled clinical trials and high quality observational studies

Klersy C, Ferlini M, Raisaro A et al. Keywords: IVUS guidance; DES implantation; MACE, mortality; MI

ABSTRACT


BACKGROUND/OBJECTIVES - Long term safety of DES, particularly regarding thrombosis is of concern. The hypothesized underlying mechanisms (stent under expansion, malapposition) could be prevented by IVUS guidance. Aim of this meta-analysis of randomized controlled clinical trials (RCT) and high quality observational cohort studies (HQ-OBS) is to quantify the potential clinical benefit of intravascular ultrasound (IVUS) guidance in drug-eluting stents (DES) implantation.


METHODS - We performed an extensive literature search for full-text articles published in 2003–2013. The primary outcome was the rate of major adverse cardiac events (MACE) in RCT and HQ-OBS; secondary outcomes were death, myocardial infarction (MI), revascularization, thrombosis and post-procedural minimum lumen diameter (MLD). Fixed/random effect relative risks (RRs) or standardized mean difference (SMD) and 95% confidence interval (95% CI) were computed for the meta-analysis.


RESULTS - Thirty-four articles were retrieved from 268 found; of these 3 were RCT and 9 were HQ-OBS; 18,707 patients were enrolled, 1037 in RCT and 17,670 in OBS. Median follow-up was 20 months. IVUS guidance was associated with a significantly lower rate of MACE (RR=0.80, 95% CI 0.71–0.89, p b 0.001), death (RR=0.60, 95% CI 0.48–0.74, p b 0.001), MI (RR=0.59, 95% CI 0.44–0.80, p=0.001) and thrombosis (RR=0.50, 95% CI 0.32–0.80, p=0.007) and larger MLD (SMD=0.15, 95% CI 0.03 to 0.27, p=0.014), but not of revascularization (RR=0.95, 95% CI 0.82–1.09, p=0.75).


CONCLUSIONS - In this meta-analysis, IVUS guidance in DES implantation appears to reduce MACE, mortality and MI, possibly by reducing thrombosis rather than restenosis rate. Patients at high risk for thrombosis might be identified as the best candidate for IVUS guidance.