The relationship between attenuated plaque identified by intravascular ultrasound and no-reflow after stenting in acute myocardial infarction: the HORIZONS-AMI (Harmonizing Outcomes With Revascularization and Stents in Acute Myocardial Infarction) trial Intravascular ultrasound-guided vs angiography-guided drug-eluting stent implantation in complex coronary lesions: Meta-analysis of randomized trials Differential prognostic effect of intravascular ultrasound use according to implanted stent length Impact of intravascular ultrasound guidance on long-term mortality in stenting for unprotected left main coronary artery stenosis Intravascular ultrasound assessment of the effects of rotational atherectomy in calcified coronary artery lesions A three-vessel virtual histology intravascular ultrasound analysis of frequency and distribution of thin-cap fibroatheromas in patients with acute coronary syndrome or stable angina pectoris Comprehensive intravascular ultrasound assessment of stent area and its impact on restenosis and adverse cardiac events in 403 patients with unprotected left main disease Impact of final stent dimensions on long-term results following sirolimus-eluting stent implantation: serial intravascular ultrasound analysis from the sirius trial Effects of Intravascular Ultrasound-Guided Versus Angiography-Guided New-Generation Drug-Eluting Stent Implantation: Meta-Analysis With Individual Patient-Level Data From 2,345 Randomized Patients Impact of post-intervention minimal stent area on 9-month follow-up patency of paclitaxel-eluting stents: an integrated intravascular ultrasound analysis from the TAXUS IV, V, and VI and TAXUS ATLAS Workhorse, Long Lesion, and Direct Stent Trials

Review Article2016 Aug 1;216:133-9.

JOURNAL:Int J Cardiol. Article Link

Intravascular ultrasound-guided drug-eluting stent implantation: An updated meta-analysis of randomized control trials and observational studies

Steinvil A, Zhang YJ, Garcia-Garcia HM et al. Keywords: Angiography; Drug-eluting stent; Intravascular ultrasound; Meta-analysis

ABSTRACT


The use of intravascular ultrasound (IVUS) guidance for drug-eluting stent (DES) optimization is limited by the number of adequately powered randomized control trials (RCTs). We performed an updated meta-analysis, including data from recently published RCTs and observational studies, by reviewing the literature in Medline and the Cochrane Library to identify studies that compared clinical outcomes between IVUS-guided and angiography-guided DES implantation from January 1995 to January 2016. This meta-analysis included 25 eligible studies, including 31,283 patients, of whom 3192 patients were enrolled in 7 RCTs. In an analysis of all 25 studies, the summary results for all the events analyzed were significantly in favor of IVUS-guided DES implantation [major adverse cardiac events (MACE, odds ratio [OR] 0.76, 95% confidence intervals [CI]: 0.70-0.82, P<0.001); death (OR 0.62, 95% CI: 0.54-0.72, P<0.001); myocardial infarction (OR 0.67, 95% CI: 0.56-0.80, P<0.001); stent thrombosis (OR 0.58, 95% CI: 0.47-0.73, P<0.001); target lesion revascularization (TLR, OR 0.77, 95% CI: 0.67-0.89, P=0.005); target vessel revascularization (TVR, OR 0.85, 95% CI: 0.76-0.95, P<0.001)]. However, in a separate analysis of RCTs, a favorable result for IVUS-guided DES implantation was found only for MACE (OR 0.66, 95% CI: 0.52-0.84, P=0.001), TLR (OR 0.61, 95% CI: 0.43-0.87, P=0.006), and TVR (OR 0.61, 95% CI: 0.41-0.90, P=0.013). IVUS-guided percutaneous coronary intervention was associated with better overall clinical outcomes than angiography-guided DES implantation. However, in a solely RCT meta-analysis, this benefit was mainly driven by reduced rates of revascularizations.