CBS 2019
CBSMD教育中心
English

IVUS Guidance

科研文章

荐读文献

Prospective application of pre-defined intravascular ultrasound criteria for assessment of intermediate left main coronary artery lesions results from the multicenter LITRO study Intravascular ultrasound findings of early stent thrombosis after primary percutaneous intervention in acute myocardial infarction: a Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction (HORIZONS-AMI) substudy Clinical impact of intravascular ultrasound guidance in drug-eluting stent implantation for unprotected left main coronary disease: pooled analysis at the patient-level of 4 registries Coronary artery imaging with intravascular high-frequency ultrasound Imaging- and physiology-guided percutaneous coronary intervention without contrast administration in advanced renal failure: a feasibility, safety, and outcome study Comparison of one-year clinical outcomes between intravascular ultrasound-guided versus angiography-guided implantation of drug-eluting stents for left main lesions: a single-center analysis of a 1,016-patient cohort Mechanisms of in-stent restenosis after drug-eluting stent implantation: intravascular ultrasound analysis The Role of Vascular Imaging in Guiding Routine Percutaneous Coronary Interventions: A Meta-Analysis of Bare Metal Stent and Drug-Eluting Stent Trials Intravascular Ultrasound Guidance Reduces Cardiac Death and Coronary Revascularization in Patients Undergoing Drug-Eluting Stent Implantation: Results From a Meta-Analysis of 9 Randomized Trials and 4724 Patients Stent underexpansion and residual reference segment stenosis are related to stent thrombosis after sirolimus-eluting stent implantation: an intravascular ultrasound study

Original ResearchFebruary 2019, Volume 35, Issue 2, pp 239–247

JOURNAL:Int J Cardiovasc Imaging Article Link

Intravascular Ultrasound Guidance Reduces Cardiac Death and Coronary Revascularization in Patients Undergoing Drug-Eluting Stent Implantation: Results From a Meta-Analysis of 9 Randomized Trials and 4724 Patients

XF Gao, ZM Wang, F Wang et al. Keywords: angiography; drug-eluting stents; intravascular ultrasound; meta-analysis; optimal criteria

ABSTRACT


Intravascular ultrasound (IVUS) guidance is not routinely performed in real-word clinical practice partly because the benefit of IVUS guidance is not well established. This updated meta-analysis aims to compare IVUS-guided and angiography-guided drug-eluting stent (DES) implantation, simultaneously stressing the value of an optimal IVUS-defined procedure. Medline, Scopus, Google Scholar, and Cochrane Controlled Trials Registry were searched for the randomized trials comparing IVUS-guided and angiography-guided DES implantation. Nine eligible randomized trials including 4,724 patients were identified. At a mean follow-up of 16.7 months, IVUS guidance was associated with a significant lower risk of major adverse cardiovascular events (MACE) [5.4% vs. 9.0%; relative risks (RR): 0.61, 95% confident interval (CI) 0.49–0.74, p < 0.001], cardiac death (0.6% vs. 1.2%; RR: 0.49, 95% CI 0.26–0.92, p = 0.03), target vessel revascularization (3.5% vs 6.1%; RR: 0.58, 95% CI 0.42–0.80, p = 0.001), target lesion revascularization (3.1% vs. 5.2%; RR: 0.59, 95% CI 0.44–0.80, p = 0.001), and definite/probable stent thrombosis (0.5% vs .1.1%; RR: 0.45, 95% CI 0.23–0.87, p = 0.02) compared with angiography guidance. No significant differences in all cause death and myocardial infarction were noted between the two groups. Subgroup analysis showed that patients who met the optimal criteria had a lower rate of MACE than those with IVUS-defined suboptimal procedure (RR: 0.33, 95% CI 0.06–0.60, p = 0.02). The present meta-analysis with the largest sample size to date demonstrates that IVUS-guided DES implantation significantly reduces cardiac death, coronary revascularization and stent thrombosis, particularly for patients with IVUS-defined optimal procedures compared with angiography guidance.