The role of integrated backscatter intravascular ultrasound in characterizing bare metal and drug-eluting stent restenotic neointima as compared to optical coherence tomography Usefulness of intravascular ultrasound to predict outcomes in short-length lesions treated with drug-eluting stents American College of Cardiology Clinical Expert Consensus Document on Standards for Acquisition, Measurement and Reporting of Intravascular Ultrasound Studies (IVUS). A report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents Comparison of intravascular ultrasound guided versus angiography guided drug eluting stent implantation: a systematic review and meta-analysis Incidence and Clinical Outcomes of Stent Fractures on the Basis of 6,555 Patients and 16,482 Drug-Eluting Stents From 4 Centers First-in-man evaluation of intravascular optical frequency domain imaging (OFDI) of Terumo: a comparison with intravascular ultrasound and quantitative coronary angiography Intracoronary stenting without anticoagulation accomplished with intravascular ultrasound guidance Intravascular ultrasound-guided implantation of drug-eluting stents to improve outcome: a meta-analysis Atherosclerotic plaque with ultrasonic attenuation affects coronary reflow and infarct size in patients with acute coronary syndrome: an intravascular ultrasound study Usefulness of minimum stent cross sectional area as a predictor of angiographic restenosis after primary percutaneous coronary intervention in acute myocardial infarction (from the HORIZONS-AMI Trial IVUS substudy)

Review Article2014 Mar;7(3):233-43.

JOURNAL:JACC Cardiovasc Interv. Article Link

Intravascular ultrasound-guided implantation of drug-eluting stents to improve outcome: a meta-analysis

Jang JS, Song YJ, Kang W et al. Keywords: drug-eluting stent(s); intravascular ultrasound; percutaneous coronary intervention

ABSTRACT


OBJECTIVES - The aim of this study was to systematically review and perform a meta-analysis of randomized trials and observational studies of intravascular ultrasound (IVUS)-guided versus angiography-guided implantation of drug-eluting stents (DES).


BACKGROUND - Although studies in the bare-metal stents era suggested that there were clinical benefits to IVUS guidance, it is still controversial whether percutaneous coronary intervention (PCI) with DES guided by IVUS leads to better clinical outcomes.


METHODS - Relevant studies published through March 31, 2013, were searched for and identified in the electronic databases. Summary estimates were obtained using a random-effects model.


RESULTS - From 138 initial citations, 3 randomized trials and 12 observational studies with 24,849 patients (11,793 IVUS-guided and 13,056 angiography-guided) were included in this study. Comparison of IVUS- versus angiography-guided PCI disclosed odds ratios (ORs) for major adverse cardiac events of 0.79 (95% confidence interval [CI]: 0.69 to 0.91; p = 0.001). IVUS-guided PCI was also associated with significantly lower rates of all-cause mortality (OR: 0.64; 95% CI: 0.51 to 0.81; p < 0.001), myocardial infarction (OR: 0.57; 95% CI: 0.42 to 0.78; p < 0.001), target vessel revascularization (OR: 0.81; 95% CI: 0.68 to 0.95; p = 0.01), and stent thrombosis (OR: 0.59; 95% CI: 0.42 to 0.82; p = 0.002). A meta-analysis of propensity-matched studies demonstrated similar results in terms of clinical outcomes, but not repeat revascularization.


CONCLUSIONS - IVUS-guided DES implantation is associated with significantly lower rates of adverse clinical events compared with angiography guidance. Further study is needed to clarify which subgroups of subjects with IVUS guidance will have greater benefit.



Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.