IVUS in bifurcation stenting: what have we learned? Stent underexpansion and residual reference segment stenosis are related to stent thrombosis after sirolimus-eluting stent implantation: an intravascular ultrasound study The Role of Vascular Imaging in Guiding Routine Percutaneous Coronary Interventions: A Meta-Analysis of Bare Metal Stent and Drug-Eluting Stent Trials Comparison of one-year clinical outcomes between intravascular ultrasound-guided versus angiography-guided implantation of drug-eluting stents for left main lesions: a single-center analysis of a 1,016-patient cohort Imaging- and physiology-guided percutaneous coronary intervention without contrast administration in advanced renal failure: a feasibility, safety, and outcome study Consensus from the 5th European Bifurcation Club meeting Intravascular ultrasound-guided systematic two-stent techniques for coronary bifurcation lesions and reduced late stent thrombosis Intravascular ultrasound assessment of the effects of rotational atherectomy in calcified coronary artery lesions Mechanisms of in-stent restenosis after drug-eluting stent implantation: intravascular ultrasound analysis Comprehensive intravascular ultrasound assessment of stent area and its impact on restenosis and adverse cardiac events in 403 patients with unprotected left main disease

Original Research2018 Feb 23;82(3):815-823.

JOURNAL:Circ J. Article Link

Intravascular Ultrasound-Derived Virtual Fractional Flow Reserve for the Assessment of Myocardial Ischemia

Seike F, Uetani T, Nishimura K et al. Keywords: Fractional flow reserve; Intravascular ultrasound; Myocardial ischemia

ABSTRACT


BACKGROUND - Fractional flow reserve (FFR) is widely used for the assessment of myocardial ischemia. Intravascular ultrasound (IVUS) is an intracoronary imaging method that provides information about lumen and vessel morphology. Previous studies on the expanded use of IVUS to identify functional ischemia have noted an association between anatomy and physiology, but IVUS-derived minimum lumen area (MLA) has a weak-moderate correlation with myocardial ischemia compared with FFR. We developed a method to calculate FFR using IVUS-derived anatomical information for the assessment of myocardial ischemia. The aims of this study were to investigate the relationship between wire-based FFR and IVUS-derived FFR (IVUS-FFR) and to compare the usefulness of IVUS-FFR and IVUS-derived MLA for functional assessment. Methods and Results:We retrospectively analyzed 50 lesions in 48 patients with coronary stenosis who underwent IVUS and FFR simultaneously. IVUS-FFR was calculated using our original algorithm and fluid dynamics. Mean percent diameter stenosis determined on quantitative coronary angiography and on FFR was 56.4±10.7 and 0.69±0.08, respectively. IVUS-FFR had a stronger linear correlation with FFR (R=0.78, P<0.001; root mean square error, 0.057 FFR units) than with IVUS-derived MLA (R=0.43, P=0.002).


CONCLUSIONS - IVUS-FFR may be a more valuable method to identify myocardial ischemia, compared with IVUS-derived MLA.