CBS 2019
CBSMD教育中心
English

IVUS Guidance

科研文章

荐读文献

Impact of the Use of Intravascular Imaging on Patients Who Underwent Orbital Atherectomy Usefulness of intravascular ultrasound to predict outcomes in short-length lesions treated with drug-eluting stents American College of Cardiology Clinical Expert Consensus Document on Standards for Acquisition, Measurement and Reporting of Intravascular Ultrasound Studies (IVUS). A report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents Comparison of intravascular ultrasound guided versus angiography guided drug eluting stent implantation: a systematic review and meta-analysis First-in-man evaluation of intravascular optical frequency domain imaging (OFDI) of Terumo: a comparison with intravascular ultrasound and quantitative coronary angiography Incidence and Clinical Outcomes of Stent Fractures on the Basis of 6,555 Patients and 16,482 Drug-Eluting Stents From 4 Centers Intracoronary stenting without anticoagulation accomplished with intravascular ultrasound guidance Usefulness of minimum stent cross sectional area as a predictor of angiographic restenosis after primary percutaneous coronary intervention in acute myocardial infarction (from the HORIZONS-AMI Trial IVUS substudy) Atherosclerotic plaque with ultrasonic attenuation affects coronary reflow and infarct size in patients with acute coronary syndrome: an intravascular ultrasound study Intravascular ultrasound-guided implantation of drug-eluting stents to improve outcome: a meta-analysis

Clinical TrialJuly 10, 2018

JOURNAL:JAMA Cardiol. Article Link

Effect of a Home-Based Wearable Continuous ECG Monitoring Patch on Detection of Undiagnosed Atrial Fibrillation The mSToPS Randomized Clinical Trial

SR Steinhubl, J Waalen, AM Edwards et al. Keywords: Atrial Fibrillation; Cardiology; Rhythm Disorders; Mobile Health and Telemedicine

ABSTRACT


IMPORTANCE - Opportunistic screening for atrial fibrillation (AF) is recommended, and improved methods of early identification could allow for the initiation of appropriate therapies to prevent the adverse health outcomes associated with AF.


OBJECTIVE -  To determine the effect of a self-applied wearable electrocardiogram (ECG) patch in detecting AF and the clinical consequences associated with such a detection strategy.

DESIGN, SETTING, and PARTICIPANTS - A direct-to-participant randomized clinical trial and prospective matched observational cohort study were conducted among members of a large national health plan. Recruitment began November 17, 2015, and was completed on October 4, 2016, and 1-year claims-based follow-up concluded in January 2018. For the clinical trial, 2659 individuals were randomized to active home-based monitoring to start immediately or delayed by 4 months. For the observational study, 2 deidentified age-, sex- and CHA2DS2-VASc–matched controls were selected for each actively monitored individual.

INTERVENTIONS - The actively monitored cohort wore a self-applied continuous ECG monitoring patch at home during routine activities for up to 4 weeks, initiated either immediately after enrolling (n = 1364) or delayed for 4 months after enrollment (n = 1291).

MAIN OUTCOMES and MEASURES -  The primary end point was the incidence of a new diagnosis of AF at 4 months among those randomized to immediate monitoring vs delayed monitoring. A secondary end point was new AF diagnosis at 1 year in the combined actively monitored groups vs matched observational controls. Other outcomes included new prescriptions for anticoagulants and health care utilization (outpatient cardiology visits, primary care visits, or AF-related emergency department visits and hospitalizations) at 1 year.

RESULTS -  The randomized groups included 2659 participants (mean [SD] age, 72.4 [7.3] years; 38.6% women), of whom 1738 (65.4%) completed active monitoring. The observational study comprised 5214 (mean [SD] age, 73.7 [7.0] years; 40.5% women; median CHA2DS2-VASc score, 3.0), including 1738 actively monitored individuals from the randomized trial and 3476 matched controls. In the randomized study, new AF was identified by 4 months in 3.9% (53/1366) of the immediate group vs 0.9% (12/1293) in the delayed group (absolute difference, 3.0% [95% CI, 1.8%-4.1%]). At 1 year, AF was newly diagnosed in 109 monitored (6.7 per 100 person-years) and 81 unmonitored (2.6 per 100 person-years; difference, 4.1 [95% CI, 3.9-4.2]) individuals. Active monitoring was associated with increased initiation of anticoagulants (5.7 vs 3.7 per 100 person-years; difference, 2.0 [95% CI, 1.9-2.2]), outpatient cardiology visits (33.5 vs 26.0 per 100 person-years; difference, 7.5 [95% CI, 7.2-7.9), and primary care visits (83.5 vs 82.6 per 100 person-years; difference, 0.9 [95% CI, 0.4-1.5]). There was no difference in AF-related emergency department visits and hospitalizations (1.3 vs 1.4 per 100 person-years; difference, 0.1 [95% CI, −0.1 to 0]).

CONCLUSIONS and RELEVANCE  Among individuals at high risk for AF, immediate monitoring with a home-based wearable ECG sensor patch, compared with delayed monitoring, resulted in a higher rate of AF diagnosis after 4 months. Monitored individuals, compared with nonmonitored controls, had higher rates of AF diagnosis, greater initiation of anticoagulants, but also increased health care resource utilization at 1 year.

TRIAL REGISTRATION -  ClinicalTrials.gov Identifier: NCT02506244