Dual Antithrombotic Therapy with Dabigatran after PCI in Atrial Fibrillation Ticagrelor plus aspirin for 1 month, followed by ticagrelor monotherapy for 23 months versus aspirin plus clopidogrel or ticagrelor for 12 months, followed by aspirin monotherapy for 12 months after implantation of a drug-eluting stent: a multicenter, open-label, randomized superiority trial Causes, Timing, and Impact of Dual Antiplatelet Therapy Interruption for Surgery (from the Patterns of Non-adherence to Anti-platelet Regimens In Stented Patients Registry) ACC/AHA Versus ESC Guidelines on Dual Antiplatelet Therapy JACC Guideline Comparison: JACC State-of-the-Art Review Benefit of switching dual antiplatelet therapy after acute coronary syndrome: the TOPIC (timing of platelet inhibition after acute coronary syndrome) randomized study Safety of six-month dual antiplatelet therapy after second-generation drug-eluting stent implantation: OPTIMA-C Randomised Clinical Trial and OCT Substudy 6- Versus 24-Month Dual Antiplatelet Therapy After Implantation of Drug-Eluting Stents in Patients Nonresistant to Aspirin Final Results of the ITALIC Trial (Is There a Life for DES After Discontinuation of Clopidogrel) Low-Dose Aspirin Discontinuation and Risk of Cardiovascular Events: A Swedish Nationwide, Population-Based Cohort Study Rationale and design of a prospective substudy of clinical endpoint adjudication processes within an investigator-reported randomised controlled trial in patients with coronary artery disease: the GLOBAL LEADERS Adjudication Sub-StudY (GLASSY) Risk of Early Adverse Events After Clopidogrel Discontinuation in Patients Undergoing Short-Term Dual Antiplatelet Therapy: An Individual Participant Data Analysis

Original Research2018 Jan;11(1):111-123.

JOURNAL:JACC Cardiovasc Imaging. Article Link

Optical Frequency Domain Imaging Versus Intravascular Ultrasound in Percutaneous Coronary Intervention (OPINION Trial) Results From the OPINION Imaging Study

Otake H, Akasaka T, OPINION Investigators et al. Keywords: intravascular ultrasound; optical coherence tomography; optical frequency domain imaging; percutaneous coronary intervention

ABSTRACT


Objectives - The authors sought to clarify how intravascular ultrasound (IVUS) and optical coherence tomography affect percutaneous coronary intervention (PCI) with current-generation drug-eluting stents in a pre-specified substudy of the OPINION (OPtical frequency domain imaging versus INtravascular ultrasound in percutaneous coronary interventiON) trial, a multicenter, prospective, randomized, noninferiority trial comparing optical frequency domain imaging (OFDI)-guided PCI with IVUS-guided PCI.


Background - The impact of these 2 imaging modalities in guiding PCI remains unknown.


Methods - Of 829 patients enrolled in the OPINION trial, 106 were included in the present imaging substudy. Their PCI was guided by either IVUS or OFDI, but all patients were imaged by both modalities after PCI and by OFDI at 8 months. Angiographic, OFDI, and IVUS images were analyzed by independent core laboratories, and statistical analysis was done independently by a dedicated institution.


Results -  A total of 103 patients underwent either OFDI-guided (n = 54) or IVUS-guided (n = 49) PCI. Immediately after PCI, OFDI-guided PCI was associated with a smaller trend of minimum stent area (5.28 ± 1.65 mm2 vs. 6.12 ± 2.34 mm2; p = 0.088), fewer proximal stent-edge hematomas (p = 0.04), and fewer irregular protrusions (p = 0.014) than IVUS-guided PCI. At 8 months, the neointima area tended to be smaller in the OFDI-guided PCI group than in the IVUS-guided PCI group (0.56 ± 0.30 mm2 vs. 0.80 ± 0.65 mm2; p = 0.057), although the percentage of uncovered struts was significantly higher in the OFDI-guided PCI group than in the IVUS-guided PCI group (6.97 ± 7.03% vs. 4.67 ± 6.43%; p = 0.039). The minimum lumen area was comparable in both groups (p = 0.18).


Conclusions - There were several differences in local findings between OFDI- and IVUS-guided PCI as expected given the different protocols for stent sizing in the 2 groups. The minimum lumen area at the 8-month follow-up was comparable, suggesting that OFDI- and IVUS-guided PCI are similarly feasible using the current-generation drug-eluting stents. (OPtical frequency domain imaging versus INtravascular ultrasound in percutaneous coronary interventiON; NCT01873222)


Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.