CBS 2019
CBSMD教育中心
English

左主干支架

科研文章

荐读文献

10-Year Outcomes of Stents Versus Coronary Artery Bypass Grafting for Left Main Coronary Artery Disease Long-Term Outcomes of Different Two-Stent Techniques With Second-Generation Drug-Eluting Stents for Unprotected Left Main Bifurcation Disease: Insights From the FAILS-2 Study Impact of SYNTAX Score on 10-Year Outcomes After Revascularization for Left Main Coronary Artery Disease Bayesian Interpretation of the EXCEL Trial and Other Randomized Clinical Trials of Left Main Coronary Artery Revascularization Left Main Percutaneous Coronary Intervention Versus Coronary Artery Bypass Grafting in Patients With Prior Cerebrovascular Disease: Results From the EXCEL Trial Intravascular Imaging and 12-Month Mortality After Unprotected Left Main Stem PCI: An Analysis From the British Cardiovascular Intervention Society Database Left Main Revascularization in 2017: Coronary Artery Bypass Grafting or Percutaneous Coronary Intervention? Revascularization of left main coronary artery Intravascular Imaging and 12-Month Mortality After Unprotected Left Main Stem PCI: An Analysis From the British Cardiovascular Intervention Society Database Percutaneous coronary intervention for the left main stem and other bifurcation lesions: 12th consensus document from the European Bifurcation Club

Clinical Trial2021 Mar 1;CIRCINTERVENTIONS120010144.

JOURNAL:Circ Cardiovasc Interv. Article Link

Primary Results of the EVOLVE Short DAPT Study: Evaluation of 3-Month Dual Antiplatelet Therapy in High Bleeding Risk Patients Treated With a Bioabsorbable Polymer-Coated Everolimus-Eluting Stent

AJ Kirtane, R Stoler, R Feldman et al. Keywords: high bleeding risk; shorter-duration DAPT; 3-month DAPT versus vs. 12-month DAPT

ABSTRACT

BACKGROUND - Prolonged dual antiplatelet therapy (DAPT) after percutaneous coronary intervention is associated with increased bleeding, despite a reduced incidence of ischemic events. The SYNERGY everolimus-eluting stent is a thin-strut platinum-chromium stent that elutes everolimus from a thin abluminal layer of bioabsorbable polymer. These design elements may facilitate rapid endothelialization and enable shorter-duration DAPT.


METHODS - EVOLVE Short DAPT prospectively evaluated the safety of 3-month DAPT in high bleeding risk patients treated with the SYNERGY everolimus-eluting stent, enrolling 2009 patients at 110 global sites. Patients with acute myocardial infarction or complex lesions were excluded. After percutaneous coronary intervention, patients were required to take DAPT (aspirin+P2Y12 inhibitor) for 3 months, except those on chronic anticoagulation in whom aspirin was optional. Patients free of events (stroke, myocardial infarction, revascularization, and stent thrombosis) who discontinued P2Y12 inhibitor at 3 months, but continued aspirin, and had at least 1 year of follow-up or an end point event were included in the primary analysis. Two powered coprimary end points were (1) death/myocardial infarction compared with a historical control and (2) study stent-related definite/probable stent thrombosis compared to a performance goal.


RESULTS - The analysis population consisted of 1487 patients. The adjusted rate of death/myocardial infarction between 3 and 15 months was 5.6% among patients receiving 3-month DAPT versus 5.7% patients in the 12-month DAPT control (propensity adjusted difference=0.12%; 97.5% upper bound=1.63% which was less than the prespecified margin of 2.52; Pnon-inferiority=0.0016). The rate of study stent-related stent thrombosis between 3-15 months was 0.2% in the 3-month DAPT group (97.5% upper bound=0.63%; P=0.0005 for comparison to 1% performance goal).


CONCLUSIONS - Favorable rates of ischemic outcomes were observed among selected high bleeding risk patients undergoing percutaneous coronary intervention with the SYNERGY everolimus-eluting stent who tolerated 3 months of P2Y12 inhibitor and then discontinued it, supporting the safety of abbreviated DAPT with this stent platform.


REGISTRATION - URL: https://www.clinicaltrials.gov; Unique identifier: NCT02605447.