Subclinical Atherosclerosis Burden by 3D Ultrasound in Mid-Life: The PESA Study Intravascular ultrasound-guided drug-eluting stent implantation is associated with improved clinical outcomes in patients with unstable angina and complex coronary artery true bifurcation lesions The outcomes of intravascular ultrasound-guided drug-eluting stent implantation among patients with complex coronary lesions: a comprehensive meta-analysis of 15 clinical trials and 8,084 patients Intravascular Ultrasound Guidance Reduces Cardiac Death and Coronary Revascularization in Patients Undergoing Drug-Eluting Stent Implantation: Results From a Meta-Analysis of 9 Randomized Trials and 4724 Patients IVUS Guidance for Coronary Revascularization: When to Start, When to Stop? Incidence and Clinical Outcomes of Stent Fractures on the Basis of 6,555 Patients and 16,482 Drug-Eluting Stents From 4 Centers Intravascular ultrasound findings of early stent thrombosis after primary percutaneous intervention in acute myocardial infarction: a Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction (HORIZONS-AMI) substudy Tissue characterisation of atherosclerotic plaque in the left main: an in vivo intravascular ultrasound radiofrequency data analysis Effect of Intravascular Ultrasound-Guided Drug-Eluting Stent Implantation: Five-Year Follow-Up of the IVUS-XPL Randomized Trial Impact of the complexity of bifurcation lesions treated with drug-eluting stents: the DEFINITION study (Definitions and impact of complEx biFurcation lesIons on clinical outcomes after percutaNeous coronary IntervenTIOn using drug-eluting steNts)

Clinical TrialMarch 2020 Vol 13, Issue 3

JOURNAL:Circulation. Article Link

Randomized Comparison of Everolimus- and Zotarolimus-Eluting Coronary Stents With Biolimus-Eluting Stents in All-Comer Patients

YJ Youn, J-W Lee, J Yoon et al.

ABSTRACT


BACKGROUND - There is limited data comparing the Xience everolimus-eluting stent (EES) and the Resolute zotarolimus-eluting stent (ZES) with the BioMatrix biolimus-eluting stent (BES).


METHODS - This open-label, randomized, noninferiority trial enrolled all-comer patients to be randomly treated with either BES, EES, or ZES in a 1:1:1 ratio in 15 centers across South Korea. The primary end point was a device-oriented composite outcome consisting of cardiac death, target-vessel myocardial infarction, and clinically indicated target lesion revascularization at 24 months. The BES was compared with the EES and the ZES by intention-to-treat analyses with a noninferiority margin of 3.8%, respectively.


RESULTS - Because of slow recruitment and low event rates, this trial was prematurely terminated after enrollment of 1935 (75%) of the intended 2580 patients. Of the 1911 patients randomized to either EES (n=638), BES (n=634), or ZES (n =639), the rate of device-oriented composite outcome was 3.6%, 2.2%, and 3.9%, respectively, at 24 months (BES versus EES: absolute risk difference 1.4% [upper limit of 1-sided 95% CI: 3.2%]; Pfor noninferiority <0.001; BES versus ZES: absolute risk difference 1.7% [upper limit of 1-sided 95% CI: 3.6%]; Pfor noninferiority <0.001).


CONCLUSIONS - The BES was noninferior to either the EES or the ZES in all-comer patients for device-oriented composite outcome at the 24-month follow-up. However, caution is advised regarding interpretation of these results due to the premature termination of this study.