CBS 2019
CBSMD教育中心
English

血管内超声指导

科研文章

荐读文献

Prospective application of pre-defined intravascular ultrasound criteria for assessment of intermediate left main coronary artery lesions results from the multicenter LITRO study Differential prognostic effect of intravascular ultrasound use according to implanted stent length Patterns of calcification in coronary artery disease. A statistical analysis of intravascular ultrasound and coronary angiography in 1155 lesions Serial intravascular ultrasound analysis of the main and side branches in bifurcation lesions treated with the T-stenting technique Intravascular ultrasound-guided percutaneous coronary intervention improves the clinical outcome in patients undergoing multiple overlapping drug-eluting stents implantation Prognostic Value of Intravascular Ultrasound in Patients With Coronary Artery Disease Long-term health outcome and mortality evaluation after invasive coronary treatment using drug eluting stents with or without the IVUS guidance. Randomized control trial. HOME DES IVUS Stent underexpansion and residual reference segment stenosis are related to stent thrombosis after sirolimus-eluting stent implantation: an intravascular ultrasound study Impact of intravascular ultrasound guidance in routine percutaneous coronary intervention for conventional lesions: data from the EXCELLENT trial Intravascular ultrasound-guided unprotected left main coronary artery stenting in the elderly

Clinical TrialVolume 11, Issue 10, May 2018

JOURNAL:JACC Cardiovasc Interv. Article Link

Impact of Optimized Procedure-Related Factors in Drug-Eluting Balloon Angioplasty for Treatment of In-Stent Restenosis

TM Rhee, JM Lee, ES Shin et al. Keywords: drug-eluting balloon; in-stent restenosis; paclitaxel-coated balloonpercutaneous coronary intervention; target lesion failure

ABSTRACT


OBJECTIVES - The aim of this study was to investigate the impact of optimizing procedure-related factors during drug-eluting balloon (DEB) angioplasty on clinical outcomes of drug-eluting stent in-stent restenosis (ISR).


BACKGOURND - Although DEB angioplasty is recommended as a reasonable option for ISR, recurrent target lesion failure (TLF) still occurs in many patients after DEB angioplasty.

METHODES - Consecutive patients with drug-eluting stent ISR treated with DEB (SeQuent Please) were collected from 4 centers in Korea. The primary outcome was 2-year TLF. Procedure-related modifiable independent predictors for TLF and their best cutoff values were determined.

RESULTS - In a total of 256 patients (309 lesions), TLF occurred in 52 patients (20.3%). Modifiable independent predictors of TLF among procedure-related factors were residual diameter stenosis after lesion preparation (residual percentage diameter stenosis [%DS]), DEB-to-stent ratio (BSR), and DEB inflation time (Tinflation), whose best cutoff values were 20%, 0.91, and 60 s, respectively. TLF rates were significantly higher in groups with residual %DS ≥20% (34.7% vs. 12.5%; adjusted hazard ratio: 2.15; 95% confidence interval: 1.86 to 2.48; p < 0.001), BSR ≤0.91 (46.4% vs. 21.9%; adjusted hazard ratio: 2.02; 95% confidence interval: 1.75 to 2.34; p < 0.001), and Tinflation ≤60 s (26.2% vs. 14.0%; adjusted hazard ratio: 1.82; 95% confidence interval: 1.36 to 2.45; p < 0.001). When classifying ISR lesions by combination of procedure-related factors, TLF occurred in 8.3% in the fully optimized procedure group (residual %DS <20%, BSR >0.91, and Tinflation >60 s) and 66.7% in the nonoptimized group (residual %DS ≥20%, BSR ≤0.91, and Tinflation ≤60 s) (p < 0.001).

CONCLUSIONS - Residual %DS after lesion preparation, BSR, and Tinflation were the only modifiable procedure-related factors in DEB angioplasty. Fully optimized DEB angioplasty with optimal lesion preparation, prolonged inflation, and sufficient dilation may play an important role in reducing TLF after DEB angioplasty.