CBS 2019
CBSMD教育中心
English

血管内超声指导

科研文章

荐读文献

Long-term survival in patients undergoing percutaneous interventions with or without intracoronary pressure wire guidance or intracoronary ultrasonographic imaging: a large cohort study Intravascular ultrasound guidance to minimize the use of iodine contrast in percutaneous coronary intervention: the MOZART (Minimizing cOntrast utiliZation With IVUS Guidance in coRonary angioplasTy) randomized controlled trial Intravascular ultrasound-guided systematic two-stent techniques for coronary bifurcation lesions and reduced late stent thrombosis Intravascular ultrasound-guided implantation of drug-eluting stents to improve outcome: a meta-analysis In vivo intravascular ultrasound-derived thin-cap fibroatheroma detection using ultrasound radiofrequency data analysis Use of Intravascular Ultrasound Imaging in Percutaneous Coronary Intervention to Treat Left Main Coronary Artery Disease Plaque composition by intravascular ultrasound and distal embolization after percutaneous coronary intervention Mechanical complications of everolimus-eluting stents associated with adverse events: an intravascular ultrasound study Clinical impact of intravascular ultrasound-guided chronic total occlusion intervention with zotarolimus-eluting versus biolimus-eluting stent implantation: randomized study Meta-analysis of outcomes after intravascular ultrasound-guided versus angiography-guided drug-eluting stent implantation in 26,503 patients enrolled in three randomized trials and 14 observational studies

Clinical TrialVolume 11, Issue 10, May 2018

JOURNAL:JACC Cardiovasc Interv. Article Link

Impact of Optimized Procedure-Related Factors in Drug-Eluting Balloon Angioplasty for Treatment of In-Stent Restenosis

TM Rhee, JM Lee, ES Shin et al. Keywords: drug-eluting balloon; in-stent restenosis; paclitaxel-coated balloonpercutaneous coronary intervention; target lesion failure

ABSTRACT


OBJECTIVES - The aim of this study was to investigate the impact of optimizing procedure-related factors during drug-eluting balloon (DEB) angioplasty on clinical outcomes of drug-eluting stent in-stent restenosis (ISR).


BACKGOURND - Although DEB angioplasty is recommended as a reasonable option for ISR, recurrent target lesion failure (TLF) still occurs in many patients after DEB angioplasty.

METHODES - Consecutive patients with drug-eluting stent ISR treated with DEB (SeQuent Please) were collected from 4 centers in Korea. The primary outcome was 2-year TLF. Procedure-related modifiable independent predictors for TLF and their best cutoff values were determined.

RESULTS - In a total of 256 patients (309 lesions), TLF occurred in 52 patients (20.3%). Modifiable independent predictors of TLF among procedure-related factors were residual diameter stenosis after lesion preparation (residual percentage diameter stenosis [%DS]), DEB-to-stent ratio (BSR), and DEB inflation time (Tinflation), whose best cutoff values were 20%, 0.91, and 60 s, respectively. TLF rates were significantly higher in groups with residual %DS ≥20% (34.7% vs. 12.5%; adjusted hazard ratio: 2.15; 95% confidence interval: 1.86 to 2.48; p < 0.001), BSR ≤0.91 (46.4% vs. 21.9%; adjusted hazard ratio: 2.02; 95% confidence interval: 1.75 to 2.34; p < 0.001), and Tinflation ≤60 s (26.2% vs. 14.0%; adjusted hazard ratio: 1.82; 95% confidence interval: 1.36 to 2.45; p < 0.001). When classifying ISR lesions by combination of procedure-related factors, TLF occurred in 8.3% in the fully optimized procedure group (residual %DS <20%, BSR >0.91, and Tinflation >60 s) and 66.7% in the nonoptimized group (residual %DS ≥20%, BSR ≤0.91, and Tinflation ≤60 s) (p < 0.001).

CONCLUSIONS - Residual %DS after lesion preparation, BSR, and Tinflation were the only modifiable procedure-related factors in DEB angioplasty. Fully optimized DEB angioplasty with optimal lesion preparation, prolonged inflation, and sufficient dilation may play an important role in reducing TLF after DEB angioplasty.