CBS 2019
CBSMD教育中心
English

血管内超声指导

科研文章

荐读文献

In-stent neoatherosclerosis: a final common pathway of late stent failure Coronary plaque redistribution after stent implantation is determined by lipid composition: A NIRS-IVUS analysis The Year in Cardiovascular Medicine 2020: Imaging: Looking back on the Year in Cardiovascular Medicine for 2020 in the field of imaging are Fausto Pinto, José Luis Zamorano and Chiara Bucciarelli-Ducci. Judy Ozkan speaks with them Comparison of paclitaxel-eluting stents (Taxus) and everolimus-eluting stents (Xience) in left main coronary artery disease with 3 years follow-up (from the ESTROFA-LM registry) Meta-analysis of outcomes after intravascular ultrasound-guided versus angiography-guided drug-eluting stent implantation in 26,503 patients enrolled in three randomized trials and 14 observational studies Intravascular Ultrasound-Guided Versus Angiography-Guided Implantation of Drug-Eluting Stent in All-Comers: The ULTIMATE trial Comprehensive intravascular ultrasound assessment of stent area and its impact on restenosis and adverse cardiac events in 403 patients with unprotected left main disease The Role of Vascular Imaging in Guiding Routine Percutaneous Coronary Interventions: A Meta-Analysis of Bare Metal Stent and Drug-Eluting Stent Trials Coronary plaque redistribution after stent implantation is determined by lipid composition: A NIRS-IVUS analysis Increased glycated albumin and decreased esRAGE levels in serum are related to negative coronary artery remodeling in patients with type 2 diabetes: an Intravascular ultrasound study

Clinical TrialSeptember 2017, Volume 10, Issue 9

JOURNAL:Circ Cardiovasc Interv. Article Link

White Blood Cell Count and Major Adverse Cardiovascular Events After Percutaneous Coronary Intervention in the Contemporary Era: Insights From the PARIS Study (Patterns of Non-Adherence to Anti-Platelet Regimens in Stented Patients Registry)

Shah B, Baber U, Mehran R et al. Keywords: white blood cell; MACE; PCI

ABSTRACT

BACKGROUND - Elevated white blood cell (WBC) count is associated with increased major adverse cardiovascular events (MACE) in the setting of acute coronary syndrome. The aim of this study was to evaluate whether similar associations persist in an all-comers population of patients undergoing percutaneous coronary intervention in the contemporary era.


METHODS AND RESULTS - In the multicenter, prospective, observational PARIS study (Patterns of Non-Adherence to Anti-Platelet Regimens in Stented Patients Registry), 4222 patients who underwent percutaneous coronary intervention in the United States and Europe between July 1, 2009, and December 2, 2010, were evaluated. The associations between baseline WBC and MACE (composite of cardiac death, stent thrombosis, spontaneous myocardial infarction, or target lesion revascularization) at 24-month follow-up were analyzed using multivariable Cox regression. Patients with higher WBC were more often younger, smokers, and with less comorbid risk factors compared with those with lower WBC. After adjustment for baseline and procedural characteristics, WBC remained independently associated with MACE (hazard ratio [HR] per 103 cells/μL increase, 1.05 [95% confidence intervals (CI), 1.02-1.09]; P=0.001), cardiac death (HR, 1.10 [95% CI, 1.05-1.17]; P<0.001), and clinically indicated target revascularization (HR, 1.04 [95% CI, 1.00-1.09]; P=0.03) but not stent thrombosis (HR, 1.07 [95% CI, 0.99-1.16]; P=0.10) or spontaneous myocardial infarction (HR, 1.03 [95% CI, 0.97-1.09]; P=0.29). The association between WBC and MACE was consistent in acute coronary syndrome and non-acute coronary syndrome presentations (interaction P=0.15).


CONCLUSIONS - Increased WBC is an independent predictor of MACE after percutaneous coronary intervention in a contemporary all-comers cohort. Further studies to delineate the underlying pathophysiologic role of elevated WBC across a spectrum of coronary artery disease presentations are warranted.


CLINICAL TRIAL REGISTRATION

URL: http://www.clinicaltrials.gov. Unique identifier: NCT00998127.


© 2017 American Heart Association, Inc.