CBS 2019
CBSMD教育中心
English

经导管主动脉瓣置换

科研文章

荐读文献

Left Ventricular Rapid Pacing Via the Valve Delivery Guidewire in Transcatheter Aortic Valve Replacement Evolving concepts in the management of antithrombotic therapy in patients undergoing transcatheter aortic valve implantation Impact of Incomplete Coronary Revascularization on Late Ischemic and Bleeding Events after Transcatheter Aortic Valve Replacement Frailty in Older Adults Undergoing Aortic Valve Replacement: The FRAILTY-AVR Study Safety and Efficacy of Transcatheter Aortic Valve Replacement With Continuation of Vitamin K Antagonists or Direct Oral Anticoagulants Acute Aortic Syndrome Revisited: JACC State-of-the-Art Review Minimum Core Data Elements for Evaluation of TAVR: A Scientific Statement by PASSION CV, HVC, and TVT Registry Empagliflozin, Health Status, and Quality of Life in Patients with Heart Failure and Preserved Ejection Fraction: The EMPEROR-Preserved Trial Guideline Update on Indications for Transcatheter Aortic Valve Implantation Based on the 2020 American College of Cardiology/American Heart Association Guidelines for Management of Valvular Heart Disease Stroke Complicating Infective Endocarditis After Transcatheter Aortic Valve Replacement

January 2019

JOURNAL:JACC: Clinical Electrophysiology Article Link

Wearable Cardioverter-Defibrillator Therapy for the Prevention of Sudden Cardiac Death A Systematic Review and Meta-Analysis

A Masri, AM Altibi, S Erqou et al. Keywords: death; meta-analysis; shock; systematic review; wearable cardioverter-defibrillator

ABSTRACT

OBJECTIVES - This study sought to synthesize the available evidence on the use of the wearable cardioverter-defibrillator (WCD).


BACKGROUND - Observational WCD studies for the prevention of sudden cardiac death have provided conflicting data. The VEST (Vest Prevention of Early Sudden Death) trial was the first randomized controlled trial (RCT) showing no reduction in sudden cardiac death as compared to medical therapy only.


METHODS - We searched PubMed, EMBASE, and Google Scholar for studies reporting on the outcomes of patients wearing WCDs from January 1, 2001, through March 20, 2018. Rates of appropriate and inappropriate WCD therapies were pooled. Estimates were derived using DerSimonian and Lairds method.


RESULTS - Twenty-eight studies were included (N = 33,242; 27 observational, 1 RCT-WCD arm). The incidence of appropriate WCD therapy was 5 per 100 persons over 3 months (95% confidence interval [CI]: 3.0 to 6.0, I2 = 93%). In studies on ischemic cardiomyopathy, the appropriate WCD therapy incidence was lower in the VEST trial (1 per 100 persons over 3 months; 95% CI: 1.0 to 2.0) as compared with observational studies (11 per 100 persons over 3 months; 95% CI: 11.0 to 20.0; I2 = 93%). The incidence of inappropriate therapy was 2 per 100 persons over 3 months (95% CI: 1.0 to 3.0; I2 = 93%). Mortality while wearing WCD was rare at 0.7 per 100 persons over 3 months (95% CI: 0.3 to 1.7; I2 = 94%).


CONCLUSIONS - The rate of appropriately treated WCD patients over 3 months of follow-up was substantial; higher in-observational studies as compared with the VEST trial. There was significant heterogeneity. More RCTs are needed to justify continued use of WCD in primary prevention.