Minimum Core Data Elements for Evaluation of TAVR: A Scientific Statement by PASSION CV, HVC, and TVT Registry Edoxaban versus Dual Antiplatelet Therapy for Leaflet Thrombosis and Cerebral Thromboembolism after TAVR: The ADAPT-TAVR Randomized Clinical Trial Third-Generation Balloon and Self-Expandable Valves for Aortic Stenosis in Large and Extra-Large Aortic Annuli From the TAVR-LARGE Registry Late kidney injury after transcatheter aortic valve replacement From organic and inorganic phosphates to valvular and vascular calcifications Bioprosthetic valve oversizing is associated with increased risk of valve thrombosis following TAVR Comparison of newer generation self-expandable vs. balloon-expandable valves in transcatheter aortic valve implantation: the randomized SOLVE-TAVI trial Transcatheter Aortic Valve Implantation Represents an Anti-Inflammatory Therapy Via Reduction of Shear Stress-Induced, Piezo-1-Mediated Monocyte Activation Association of Smoking Status With Long‐Term Mortality and Health Status After Transcatheter Aortic Valve Replacement: Insights From the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry 2020 ACC Expert Consensus Decision Pathway on Management of Conduction Disturbances in Patients Undergoing Transcatheter Aortic Valve Replacement A Report of the American College of Cardiology Solution Set Oversight Committee

Clinical Case Study2020 Nov 14;ehaa817.

JOURNAL:Eur Heart J. Article Link

Chimney technique in a TAVR-in-TAVR procedure with high risk of left main artery ostium occlusion

A Dibie, Q Landolff, A Veugeois et al. Keywords: clinical case; chimney technique; TAVR-in-TAVR procedure; left main artery ostium occlusion

ABSTRACT

An 87-year-old woman was referred to our centre for a valve-in-valve transcatheter aortic valve replacement (TAVR). She underwent a TAVR procedure with implantation of a SAPIEN XT 26 mm (Edwards Lifesciences) bioprosthesis 7 years before but subsequently developed symptomatic aortic valve failure (mean gradient = 64 mmHg).

Pre-procedural computed tomography (CT) scan identified a low height between the valvular plane and left main coronary artery (LMA) ostium equal to 2.7 mm (Panel A1). Valve simulation technique was applied: the virtual transcatheter heart valve/coronary distance was measured at 4.0 mm (Panel A2). The coronary angiography revealed no recurrent stenosis (Panel B)....