CBS 2019
CBSMD教育中心
中 文

科学研究

Abstract

Recommended Article

Optical Frequency Domain Imaging Versus Intravascular Ultrasound in Percutaneous Coronary Intervention (OPINION Trial) Results From the OPINION Imaging Study Intravascular Ultrasound to Guide Left Main Stem Intervention: A Sub-Study of the NOBLE Trial The year in cardiovascular medicine 2020: heart failure and cardiomyopathies Atrial Fibrillation and the Prognostic Performance of Biomarkers in Heart Failure Feasibility of Coronary Access and Aortic Valve Reintervention in Low-Risk TAVR Patients Impact of plaque components on no-reflow phenomenon after stent deployment in patients with acute coronary syndrome: a virtual histology-intravascular ultrasound analysis Nitrosative stress drives heart failure with preserved ejection fraction Unexpectedly Low Natriuretic Peptide Levels in Patients With Heart Failure

Clinical Trial2018 Aug;30(8):276-281.

JOURNAL:J Invasive Cardiol. Article Link

Long-Term Outcomes of Different Two-Stent Techniques With Second-Generation Drug-Eluting Stents for Unprotected Left Main Bifurcation Disease: Insights From the FAILS-2 Study

Pavani M, Conrotto F, Cerrato E et al. Keywords: LM bifurcation disease; T-stenting technique; culotte technique; mini-crush technique; two-stent strategies

ABSTRACT


OBJECTIVES - To investigate the long-term clinical outcomes of second-generation drug-eluting stent (2G-DES) implantation for the treatment of complex unprotected left main coronary artery (ULMCA) bifurcation lesions with different two-stent techniques.


BACKGROUND - Several two-stent techniques for ULMCA bifurcation lesions have been described. However, a paucity of data exists regarding the optimal strategy, especially in the 2G-DES era.

METHODS - The FAILS-2 registry enrolled 1270 consecutive patients treated for ULMCA stenosis with 2G-DES. We compared long-term outcomes of different two-stent strategies in patients who underwent PCI for complex ULMCA bifurcation disease. The primary endpoints were the incidence of death and major adverse cardiac events (MACE, defined as a composite of all-cause death, myocardial infarction [MI], target-lesion revascularization [TLR], and stent thrombosis [ST]) at long-term follow-up.

RESULTS - A total of 238 patients were included in the present analysis. T-stenting strategy was used in 66 patients, mini-crush in 104 patients, and culotte in 68 patients. After a median follow-up of 2.27 years, death rates were comparable for the three techniques (9.3% T-stenting vs 9.0% mini-crush vs 4.5% culotte [P=.48]). MACE rates were also similar between the three groups (22% T-stenting vs 26% mini-crush vs 31% culotte [P=.50]). Finally, we showed no differences in MI, ST, and TLR rates between groups. At multivariate analysis, no significant advantage of one technique over the others was observed.

CONCLUSION - T-stenting, mini-crush, and culotte techniques using 2G-DES for ULMCA bifurcation disease showed similar clinical outcomes at long-term follow-up. MACE rates were mainly driven by in-stent restenosis at the circumflex ostium.