CBS 2019
CBSMD教育中心
中 文

科学研究

Abstract

Recommended Article

Comparison of newer generation self-expandable vs. balloon-expandable valves in transcatheter aortic valve implantation: the randomized SOLVE-TAVI trial Baseline Characteristics and Risk Profiles of Participants in the ISCHEMIA Randomized Clinical Trial High-Risk Coronary Plaque Regression After Intensive Lifestyle Intervention in Nonbstructive Coronary Disease: A Randomized Study Right ventricular function and outcome in patients undergoing transcatheter aortic valve replacement Impact of myocardial fibrosis on left ventricular remodelling, recovery, and outcome after transcatheter aortic valve implantation in different haemodynamic subtypes of severe aortic stenosis Dual Antiplatelet Therapy Duration in Medically Managed Acute Coronary Syndrome Patients: Sub-Analysis of the OPT-CAD Study Clinical Outcomes Following Intravascular Imaging-Guided Versus Coronary Angiography-Guided Percutaneous Coronary Intervention With Stent Implantation: A Systematic Review and Bayesian Network Meta-Analysis of 31 Studies and 17,882 Patients Coronary Access After TAVR With a Self-Expanding Bioprosthesis: Insights From Computed Tomography

Clinical Trial2018 Aug;30(8):276-281.

JOURNAL:J Invasive Cardiol. Article Link

Long-Term Outcomes of Different Two-Stent Techniques With Second-Generation Drug-Eluting Stents for Unprotected Left Main Bifurcation Disease: Insights From the FAILS-2 Study

Pavani M, Conrotto F, Cerrato E et al. Keywords: LM bifurcation disease; T-stenting technique; culotte technique; mini-crush technique; two-stent strategies

ABSTRACT


OBJECTIVES - To investigate the long-term clinical outcomes of second-generation drug-eluting stent (2G-DES) implantation for the treatment of complex unprotected left main coronary artery (ULMCA) bifurcation lesions with different two-stent techniques.


BACKGROUND - Several two-stent techniques for ULMCA bifurcation lesions have been described. However, a paucity of data exists regarding the optimal strategy, especially in the 2G-DES era.

METHODS - The FAILS-2 registry enrolled 1270 consecutive patients treated for ULMCA stenosis with 2G-DES. We compared long-term outcomes of different two-stent strategies in patients who underwent PCI for complex ULMCA bifurcation disease. The primary endpoints were the incidence of death and major adverse cardiac events (MACE, defined as a composite of all-cause death, myocardial infarction [MI], target-lesion revascularization [TLR], and stent thrombosis [ST]) at long-term follow-up.

RESULTS - A total of 238 patients were included in the present analysis. T-stenting strategy was used in 66 patients, mini-crush in 104 patients, and culotte in 68 patients. After a median follow-up of 2.27 years, death rates were comparable for the three techniques (9.3% T-stenting vs 9.0% mini-crush vs 4.5% culotte [P=.48]). MACE rates were also similar between the three groups (22% T-stenting vs 26% mini-crush vs 31% culotte [P=.50]). Finally, we showed no differences in MI, ST, and TLR rates between groups. At multivariate analysis, no significant advantage of one technique over the others was observed.

CONCLUSION - T-stenting, mini-crush, and culotte techniques using 2G-DES for ULMCA bifurcation disease showed similar clinical outcomes at long-term follow-up. MACE rates were mainly driven by in-stent restenosis at the circumflex ostium.