CBS 2019
CBSMD教育中心
中 文

科学研究

Abstract

Recommended Article

Applications of left ventricular strain measurements to patients undergoing chemotherapy Comparison of new-generation drug-eluting stents versus drug-coated balloon for in-stent restenosis: a meta-analysis of randomised controlled trials Sustainable Antirestenosis Effect With a Low-Dose Drug-Coated Balloon: The ILLUMENATE European Randomized Clinical Trial 2-Year Results Multicentre, randomized comparison of two-stent and provisional stenting techniques in patients with complex coronary bifurcation lesions: the DEFINITION II trial In vivo comparison of lipid-rich plaque on near-infrared spectroscopy with histopathological analysis of coronary atherectomy specimens Comparison of the safety and efficacy of two types of drug-eluting balloons (RESTORE DEB and SeQuent® Please) in the treatment of coronary in-stent restenosis: study protocol for a randomized controlled trial (RESTORE ISR China) Long-term clinical outcomes after treatment of stent restenosis with two drug-coated balloons Percutaneous Pulmonary Angioplasty for Patients With Takayasu Arteritis and Pulmonary Hypertension

Clinical Trial2018 Aug;30(8):276-281.

JOURNAL:J Invasive Cardiol. Article Link

Long-Term Outcomes of Different Two-Stent Techniques With Second-Generation Drug-Eluting Stents for Unprotected Left Main Bifurcation Disease: Insights From the FAILS-2 Study

Pavani M, Conrotto F, Cerrato E et al. Keywords: LM bifurcation disease; T-stenting technique; culotte technique; mini-crush technique; two-stent strategies

ABSTRACT


OBJECTIVES - To investigate the long-term clinical outcomes of second-generation drug-eluting stent (2G-DES) implantation for the treatment of complex unprotected left main coronary artery (ULMCA) bifurcation lesions with different two-stent techniques.


BACKGROUND - Several two-stent techniques for ULMCA bifurcation lesions have been described. However, a paucity of data exists regarding the optimal strategy, especially in the 2G-DES era.

METHODS - The FAILS-2 registry enrolled 1270 consecutive patients treated for ULMCA stenosis with 2G-DES. We compared long-term outcomes of different two-stent strategies in patients who underwent PCI for complex ULMCA bifurcation disease. The primary endpoints were the incidence of death and major adverse cardiac events (MACE, defined as a composite of all-cause death, myocardial infarction [MI], target-lesion revascularization [TLR], and stent thrombosis [ST]) at long-term follow-up.

RESULTS - A total of 238 patients were included in the present analysis. T-stenting strategy was used in 66 patients, mini-crush in 104 patients, and culotte in 68 patients. After a median follow-up of 2.27 years, death rates were comparable for the three techniques (9.3% T-stenting vs 9.0% mini-crush vs 4.5% culotte [P=.48]). MACE rates were also similar between the three groups (22% T-stenting vs 26% mini-crush vs 31% culotte [P=.50]). Finally, we showed no differences in MI, ST, and TLR rates between groups. At multivariate analysis, no significant advantage of one technique over the others was observed.

CONCLUSION - T-stenting, mini-crush, and culotte techniques using 2G-DES for ULMCA bifurcation disease showed similar clinical outcomes at long-term follow-up. MACE rates were mainly driven by in-stent restenosis at the circumflex ostium.