CBS 2019
CBSMD教育中心
中 文

科学研究

Abstract

Recommended Article

Changes in high-sensitivity troponin after drug-coated balloon angioplasty for drug-eluting stent restenosis Effects of Liraglutide on Cardiovascular Outcomes in Patients With Diabetes With or Without Heart Failure Transverse partial stent ablation with rotational atherectomy for suboptimal culotte technique in left main stem bifurcation Effect of Side Branch Predilation in Coronary Bifurcation Stenting With the Provisional Approach - Results From the COBIS (Coronary Bifurcation Stenting) II Registry Aspirin in the primary and secondary prevention of vascular disease: collaborative meta-analysis of individual participant data from randomised trials Positive remodelling of coronary arteries on computed tomography coronary angiogram: an observational study sST2 Predicts Outcome in Chronic Heart Failure Beyond NT−proBNP and High-Sensitivity Troponin T Potential protective mechanisms of green tea polyphenol EGCG against COVID-19

Clinical Trial2018 Aug;30(8):276-281.

JOURNAL:J Invasive Cardiol. Article Link

Long-Term Outcomes of Different Two-Stent Techniques With Second-Generation Drug-Eluting Stents for Unprotected Left Main Bifurcation Disease: Insights From the FAILS-2 Study

Pavani M, Conrotto F, Cerrato E et al. Keywords: LM bifurcation disease; T-stenting technique; culotte technique; mini-crush technique; two-stent strategies

ABSTRACT


OBJECTIVES - To investigate the long-term clinical outcomes of second-generation drug-eluting stent (2G-DES) implantation for the treatment of complex unprotected left main coronary artery (ULMCA) bifurcation lesions with different two-stent techniques.


BACKGROUND - Several two-stent techniques for ULMCA bifurcation lesions have been described. However, a paucity of data exists regarding the optimal strategy, especially in the 2G-DES era.

METHODS - The FAILS-2 registry enrolled 1270 consecutive patients treated for ULMCA stenosis with 2G-DES. We compared long-term outcomes of different two-stent strategies in patients who underwent PCI for complex ULMCA bifurcation disease. The primary endpoints were the incidence of death and major adverse cardiac events (MACE, defined as a composite of all-cause death, myocardial infarction [MI], target-lesion revascularization [TLR], and stent thrombosis [ST]) at long-term follow-up.

RESULTS - A total of 238 patients were included in the present analysis. T-stenting strategy was used in 66 patients, mini-crush in 104 patients, and culotte in 68 patients. After a median follow-up of 2.27 years, death rates were comparable for the three techniques (9.3% T-stenting vs 9.0% mini-crush vs 4.5% culotte [P=.48]). MACE rates were also similar between the three groups (22% T-stenting vs 26% mini-crush vs 31% culotte [P=.50]). Finally, we showed no differences in MI, ST, and TLR rates between groups. At multivariate analysis, no significant advantage of one technique over the others was observed.

CONCLUSION - T-stenting, mini-crush, and culotte techniques using 2G-DES for ULMCA bifurcation disease showed similar clinical outcomes at long-term follow-up. MACE rates were mainly driven by in-stent restenosis at the circumflex ostium.