CBS 2019
CBSMD教育中心
中 文

科学研究

Abstract

Recommended Article

Volumetric characterization of human coronary calcification by frequency-domain optical coherence tomography Left main coronary artery compression in pulmonary hypertension Robustness of Fractional Flow Reserve for Lesion Assessment in Non-Infarct-Related Arteries of Patients With Myocardial Infarction Diagnostic accuracy of fractional flow reserve from anatomic CT angiography Left main coronary artery disease: importance, diagnosis, assessment, and management Comparison of Coronary Intimal Plaques by Optical Coherence Tomography in Arteries With Versus Without Internal Running Vasa Vasorum Long-term clinical outcome after fractional flow reserve-guided treatment in patients with angiographically equivocal left main coronary artery stenosis Experimental basis of determining maximum coronary, myocardial, and collateral blood flow by pressure measurements for assessing functional stenosis severity before and after percutaneous transluminal coronary angioplasty

Clinical TrialSeptember 2018

JOURNAL:J Am Coll Cardiol. Article Link

Intravascular Ultrasound-Guided Versus Angiography-Guided Implantation of Drug-Eluting Stent in All-Comers: The ULTIMATE trial

JJ Zhang, XF Gao, SL Chen et al. Keywords: Intravascular ultrasound (IVUS)-guided drug-eluting stent (DES) implantation; angiography guidance; MACE

ABSTRACT


BACKGROUND - Intravascular ultrasound (IVUS)-guided drug-eluting stent (DES) implantation is associated with less major adverse cardiovascular events (MACE) compared with angiography guidance for patients with individual lesion subset. However, the beneficiary effect on MACE outcome of IVUS guidance over angiography guidance in all-comers who undergo DES implantation still remains understudied.


OBJECTIVES -This study aimed to determine the benefits of IVUS guidance over angiography guidance during DES implantation in all-comer patients.


METHODS - A total of 1448 all-comer patients who required DES implantation were randomly assigned (1:1 ratio) to either IVUS guidance or Angiography guidance group. Primary endpoint was target vessel failure (TVF) at 12 months, including cardiac death, target vessel myocardial infarction (TV-MI), and clinically-driven target vessel revascularization (TVR). Procedure was defined as success if IVUS-defined all optimal criteria were met.


RESULTS - At 12 months follow-up, 60 (4.2%) TVFs occurred, with 21 (2.9%) in the IVUS group and 39 (5.4%) in the Angiography group (hazard ratio [HR] 0.530, 95% confidence interval [CI] 0.312-0.901; p=0.019). In the IVUS group, TVF was recorded in 1.6% of patients with successful procedures, compared to 4.4% in patients who failed to achieve all optimal criteria (HR: 0.349; 95%CI: 0.135-0.898; p=0.029). The significant reduction of clinically-driven target lesion revascularization (TLR) or definite stent thrombosis (HR: 0.407; 95% CI: 0.188-0.880; p=0.018) based-on lesion level analysis by IVUS guidance was not achieved when patient-level analysis was performed.


CONCLUSIONS -The present study demonstrated that IVUS-guided DES implantation significantly improved clinical outcome in all-comers, particularly for patients who had an IVUS-defined optimal procedure, compared to angiography guidance.


CONSENDED ABSTRACT - A total of 1448 all-comers who required DES implantation were randomly assigned to either IVUS or Angiography guidance group. At 12 months follow-up, TVF occurred in 21 patients (2.9%) in IVUS guidance group and 39 patients (5.4%) in Angiography guidance group (p=0.019). In the IVUS group, TVF was recorded in 1.6% of patients with successful procedures, compared to 4.4% in patients who failed to achieve all optimal criteria (p=0.029). Compared to Angiography guidance, IVUS guidance benefited similarly for patients with either ACC/AHA-defined B2/C lesions or A/B1 lesions in terms of composite of clinically-driven TLR or definite ST.