CBS 2019
CBSMD教育中心
中 文

科学研究

Abstract

Recommended Article

Door to Balloon Time: Is There a Point That Is Too Short? Comparison of Outcomes of Patients With ST-Segment Elevation Myocardial Infarction Treated by Primary Percutaneous Coronary Intervention Analyzed by Age Groups (<75, 75 to 85, and >85 Years); (Results from the Bremen STEMI Registry) Volume brings value Location of the culprit coronary lesion and its association with delay in door-to-balloon time (from a multicenter registry of primary percutaneous coronary intervention) Percutaneous coronary intervention reduces mortality in myocardial infarction patients with comorbidities: Implications for elderly patients with diabetes or kidney disease Mortality and morbidity in acutely ill adults treated with liberal versus conservative oxygen therapy (IOTA): a systematic review and meta-analysis Remote ischaemic conditioning and healthcare system delay in patients with ST-segment elevation myocardial infarction PCI Strategies in Patients with Acute Myocardial Infarction and Cardiogenic Shock

Original ResearchFebruary 2019, Volume 35, Issue 2, pp 239–247

JOURNAL:Int J Cardiovasc Imaging Article Link

Intravascular Ultrasound Guidance Reduces Cardiac Death and Coronary Revascularization in Patients Undergoing Drug-Eluting Stent Implantation: Results From a Meta-Analysis of 9 Randomized Trials and 4724 Patients

XF Gao, ZM Wang, F Wang et al. Keywords: angiography; drug-eluting stents; intravascular ultrasound; meta-analysis; optimal criteria

ABSTRACT


Intravascular ultrasound (IVUS) guidance is not routinely performed in real-word clinical practice partly because the benefit of IVUS guidance is not well established. This updated meta-analysis aims to compare IVUS-guided and angiography-guided drug-eluting stent (DES) implantation, simultaneously stressing the value of an optimal IVUS-defined procedure. Medline, Scopus, Google Scholar, and Cochrane Controlled Trials Registry were searched for the randomized trials comparing IVUS-guided and angiography-guided DES implantation. Nine eligible randomized trials including 4,724 patients were identified. At a mean follow-up of 16.7 months, IVUS guidance was associated with a significant lower risk of major adverse cardiovascular events (MACE) [5.4% vs. 9.0%; relative risks (RR): 0.61, 95% confident interval (CI) 0.49–0.74, p < 0.001], cardiac death (0.6% vs. 1.2%; RR: 0.49, 95% CI 0.26–0.92, p = 0.03), target vessel revascularization (3.5% vs 6.1%; RR: 0.58, 95% CI 0.42–0.80, p = 0.001), target lesion revascularization (3.1% vs. 5.2%; RR: 0.59, 95% CI 0.44–0.80, p = 0.001), and definite/probable stent thrombosis (0.5% vs .1.1%; RR: 0.45, 95% CI 0.23–0.87, p = 0.02) compared with angiography guidance. No significant differences in all cause death and myocardial infarction were noted between the two groups. Subgroup analysis showed that patients who met the optimal criteria had a lower rate of MACE than those with IVUS-defined suboptimal procedure (RR: 0.33, 95% CI 0.06–0.60, p = 0.02). The present meta-analysis with the largest sample size to date demonstrates that IVUS-guided DES implantation significantly reduces cardiac death, coronary revascularization and stent thrombosis, particularly for patients with IVUS-defined optimal procedures compared with angiography guidance.