CBS 2019
CBSMD教育中心
中 文

科学研究

Abstract

Recommended Article

In-Hospital Costs and Costs of Complications of Chronic Total Occlusion Angioplasty Insights From the OPEN-CTO Registry Long-term outcomes of rotational atherectomy of underexpanded stents. A single center experience Double kissing crush in left main coronary bifurcation lesions: A crushing blow to the rival stenting techniques Chronic Kidney Disease and Coronary Artery Disease Left Ventricular Assist Devices: Synergistic Model Between Technology and Medicine Diagnostic performance of stress perfusion cardiac magnetic resonance for the detection of coronary artery disease: A systematic review and meta-analysis Catheterization Laboratory Considerations During the Coronavirus (COVID-19) Pandemic: From the ACC’s Interventional Council and SCAI Drug-eluting balloons in coronary interventions: the quiet revolution?

Original ResearchFebruary 2019, Volume 35, Issue 2, pp 239–247

JOURNAL:Int J Cardiovasc Imaging Article Link

Intravascular Ultrasound Guidance Reduces Cardiac Death and Coronary Revascularization in Patients Undergoing Drug-Eluting Stent Implantation: Results From a Meta-Analysis of 9 Randomized Trials and 4724 Patients

XF Gao, ZM Wang, F Wang et al. Keywords: angiography; drug-eluting stents; intravascular ultrasound; meta-analysis; optimal criteria

ABSTRACT


Intravascular ultrasound (IVUS) guidance is not routinely performed in real-word clinical practice partly because the benefit of IVUS guidance is not well established. This updated meta-analysis aims to compare IVUS-guided and angiography-guided drug-eluting stent (DES) implantation, simultaneously stressing the value of an optimal IVUS-defined procedure. Medline, Scopus, Google Scholar, and Cochrane Controlled Trials Registry were searched for the randomized trials comparing IVUS-guided and angiography-guided DES implantation. Nine eligible randomized trials including 4,724 patients were identified. At a mean follow-up of 16.7 months, IVUS guidance was associated with a significant lower risk of major adverse cardiovascular events (MACE) [5.4% vs. 9.0%; relative risks (RR): 0.61, 95% confident interval (CI) 0.49–0.74, p < 0.001], cardiac death (0.6% vs. 1.2%; RR: 0.49, 95% CI 0.26–0.92, p = 0.03), target vessel revascularization (3.5% vs 6.1%; RR: 0.58, 95% CI 0.42–0.80, p = 0.001), target lesion revascularization (3.1% vs. 5.2%; RR: 0.59, 95% CI 0.44–0.80, p = 0.001), and definite/probable stent thrombosis (0.5% vs .1.1%; RR: 0.45, 95% CI 0.23–0.87, p = 0.02) compared with angiography guidance. No significant differences in all cause death and myocardial infarction were noted between the two groups. Subgroup analysis showed that patients who met the optimal criteria had a lower rate of MACE than those with IVUS-defined suboptimal procedure (RR: 0.33, 95% CI 0.06–0.60, p = 0.02). The present meta-analysis with the largest sample size to date demonstrates that IVUS-guided DES implantation significantly reduces cardiac death, coronary revascularization and stent thrombosis, particularly for patients with IVUS-defined optimal procedures compared with angiography guidance.