CBS 2019
CBSMD教育中心
中 文

科学研究

Abstract

Recommended Article

Risk of Myocardial Infarction in Anticoagulated Patients With Atrial Fibrillation Association Between Diastolic Dysfunction and Health Status Outcomes in Patients Undergoing Transcatheter Aortic Valve Replacement Risk Stratification Guided by the Index of Microcirculatory Resistance and Left Ventricular End-Diastolic Pressure in Acute Myocardial Infarction Prognostic Value of Fractional Flow Reserve Measured Immediately After Drug-Eluting Stent Implantation Long-Term Coronary Functional Assessment of the Infarct-Related Artery Treated With Everolimus-Eluting Bioresorbable Scaffolds or Everolimus-Eluting Metallic Stents: Insights of the TROFI II Trial Canadian SCAD Cohort Study: Shedding Light on SCAD From a United Front Everolimus-Eluting Bioresorbable Scaffolds Versus Everolimus-Eluting Metallic Stents A sirolimus-eluting bioabsorbable polymer-coated stent (MiStent) versus an everolimus-eluting durable polymer stent (Xience) after percutaneous coronary intervention (DESSOLVE III): a randomised, single-blind, multicentre, non-inferiority, phase 3 trial

Original Research2021 Jun;14(6):1235-1245.

JOURNAL:JACC Cardiovasc Imaging. Article Link

Pancoronary Plaque Characteristics in STEMI Caused by Culprit Plaque Erosion Versus Rupture: 3-Vessel OCT Study

MH Cao , LL Zhao, B Yu et al.

ABSTRACT

OBJECTIVES -  This study sought to investigate nonculprit plaque characteristics in patients with ST-segment elevation myocardial infarction (STEMI) presenting with plaque erosion (PE) and plaque rupture (PR). Pancoronary vulnerability was considered at nonculprit sites: 1) the CLIMA (Relationship Between OCT Coronary Plaque Morphology and Clinical Outcome) study (NCT02883088) defined high-risk plaques with simultaneous presence of 4 optical coherence tomography (OCT) features (minimum lumen area <3.5 mm2; fibrous cap thickness [FCT] <75 μm; maximum lipid arc >180º; and macrophage accumulation); and 2) the presence of plaque ruptures or thin-cap fibroatheromas (TCFA).

 

BACKGROUND -  PE is a unique clinical entity associated with better outcomes than PR. There is limited evidence regarding pancoronary plaque characteristics of patients with culprit PE versus culprit PR.

 

METHODS -  Between October 2016 and September 2018, 523 patients treated by 3-vessel OCT at the time of primary percutaneous intervention were included with 152 patients excluded from final analysis.

 

RESULTS -  Overall, 458 nonculprit plaques were identified in 202 STEMI patients with culprit PE; and 1,027 nonculprit plaques were identified in 321 STEMI patients with culprit PR. At least 1 CLIMA-defined OCT nonculprit high-risk plaque was seen in 11.4% of patients with culprit PE, but twice as many patients were seen with culprit PR (25.2%; p < 0.001). This proportion was also seen when individual high-risk features were analyzed separately. When patients with PE were divided by a heterogeneous substrate (fibrous or lipid-rich plaque) underlying the culprit site, the prevalence of nonculprits with FCT <75 μm, macrophages, and TCFA showed a significant gradient from PE(Fibrous) to PElipid-rich plaque (LRP) to PR. Interestingly, nonculprit rupture was rarely found in patients with culprit PE(Fibrous) (1.9%), although it was exhibited with comparable prevalence in patients with culprit PE(LRP) (16.3%) versus PR (17.8%). Culprit PE predicted decreased pancoronary vulnerability independent of conventional risk factors.

 

CONCLUSIONS -  STEMI patients with culprit PE have a limited pancoronary vulnerability that may explain better outcomes in these patients than in STEMI patients with culprit PR.