CBS 2019
CBSMD教育中心
中 文

Stenting Left Main

Abstract

Recommended Article

Why NOBLE and EXCEL Are Consistent With Each Other and With Previous Trials Ten-Year All-Cause Death According to Completeness of Revascularization in Patients With Three-Vessel Disease or Left Main Coronary Artery Disease: Insights From the SYNTAX Extended Survival Study Long-term results after PCI of unprotected distal left main coronary artery stenosis: the Bifurcations Bad Krozingen (BBK)-Left Main Registry Current treatment of significant left main coronary artery disease: A review Surgical ineligibility and mortality among patients with unprotected left main or multivessel coronary artery disease undergoing percutaneous coronary intervention Patient selection and percutaneous technique of unprotected left main revascularization Comparison of Outcomes of Percutaneous Coronary Intervention on Native Coronary Arteries Versus on Saphenous Venous Aorta Coronary Conduits in Patients With Low Left Ventricular Ejection Fraction and Impella Device Implantation Achieved or Attempted (from the PROTECT II Randomized Trial and the cVAD Registry) Percutaneous Coronary Intervention Versus Coronary Artery Bypass Grafting in Patients With Left Main and Multivessel Coronary Artery Disease: Do We Have the Evidence?

Review Article2017 Jun 13;69(23):2845-2861.

JOURNAL:J Am Coll Cardiol. Article Link

Left Ventricular Assist Devices for Lifelong Support

Pinney SP, Anyanwu AC, Lala A et al. Keywords: cardiothoracic surgery; heart failure; hemocompatibility

ABSTRACT


Continuous-flow left ventricular assist devices (LVADs) have revolutionized advanced heart failure care. These compact, fully implantable heart pumps are capable of providing meaningful increases in survival, functional capacity, and quality of life. Implantation volumes continue to grow, but several challenges remain to be overcome before LVADs will be considered as the therapy of choice for all patients with advanced heart failure. They must be able to consistently extend survival for the long term (7 to 10 years), rather than the midterm (3 to 5 years) more typical of contemporary devices; they must incorporate design elements that reduce shear stress and avoid stasis to reduce the frequent adverse events of bleeding, stroke, and pump thrombosis; and they must become more cost-effective. The advancements in engineering, implantation technique, and medical management detailed in this review will highlight the progress made toward achieving lifelong LVAD support and the challenges that remain.