CBS 2019
CBSMD教育中心
中 文

IVUS Guidance

Abstract

Recommended Article

The relationship between attenuated plaque identified by intravascular ultrasound and no-reflow after stenting in acute myocardial infarction: the HORIZONS-AMI (Harmonizing Outcomes With Revascularization and Stents in Acute Myocardial Infarction) trial Impact of intravascular ultrasound guidance on long-term mortality in stenting for unprotected left main coronary artery stenosis Impact of final stent dimensions on long-term results following sirolimus-eluting stent implantation: serial intravascular ultrasound analysis from the sirius trial Effects of Intravascular Ultrasound-Guided Versus Angiography-Guided New-Generation Drug-Eluting Stent Implantation: Meta-Analysis With Individual Patient-Level Data From 2,345 Randomized Patients A three-vessel virtual histology intravascular ultrasound analysis of frequency and distribution of thin-cap fibroatheromas in patients with acute coronary syndrome or stable angina pectoris Intravascular ultrasound assessment of the effects of rotational atherectomy in calcified coronary artery lesions Comprehensive intravascular ultrasound assessment of stent area and its impact on restenosis and adverse cardiac events in 403 patients with unprotected left main disease Impact of post-intervention minimal stent area on 9-month follow-up patency of paclitaxel-eluting stents: an integrated intravascular ultrasound analysis from the TAXUS IV, V, and VI and TAXUS ATLAS Workhorse, Long Lesion, and Direct Stent Trials

Original Research2005 Feb 1;45(3):351-6.

JOURNAL:J Am Coll Cardiol. Article Link

Sirolimus-eluting stent implantation for unprotected left main coronary artery stenosis: comparison with bare metal stent implantation

Park SJ, Kim YH, Lee BK et al. Keywords: Sirolimus-eluting stent; unprotected left main coronary artery stenosis; bare metal stent

ABSTRACT


OBJECTIVESThis study was designed to compare the clinical and angiographic outcomes of sirolimus-eluting stent (SES) and bare metal stent (BMS) implantation for unprotected left main coronary artery (LMCA) stenosis.


BACKGROUNDThe safety and effectiveness of SES implantation for unprotected LMCA stenosis have not been ascertained.

METHODSElective SES implantation for de novo unprotected LMCA stenosis was performed in 102 consecutive patients with preserved left ventricular function from March 2003 to March 2004. Data from this group were compared to those from 121 patients treated with BMS during the preceding two years.

RESULTSCompared to the BMS group, the SES group received more direct stenting, had fewer debulking atherectomies, had a greater number of stents, had more segments stented, and underwent more bifurcation stenting. The procedural success rate was 100% for both groups. There were no incidents of death, stent thrombosis, Q-wave myocardial infarction (MI), or emergent bypass surgery during hospitalization in either group. Despite less acute gain (2.06 +/- 0.56 mm vs. 2.73 +/- 0.73 mm, p < 0.001) in the SES group, SES patients showed a lower late lumen loss (0.05 +/- 0.57 mm vs. 1.27 +/- 0.90 mm, p < 0.001) and a lower six-month angiographic restenosis rate (7.0% vs. 30.3%, p < 0.001) versus the BMS group. At 12 months, the rate of freedom from death, MI, and target lesion revascularization was 98.0 +/- 1.4% in the SES group and 81.4 +/- 3.7% in the BMS group (p = 0.0003).

CONCLUSIONSSirolimus-eluting stent implantation for unprotected LMCA stenosis appears safe with regard to acute and midterm complications and is more effective in preventing restenosis compared to BMS implantation.