Assessment Of Proximal Left Anterior Descending Artery Size By Intravascular Ultrasound For Optimal Stent Sizing Attenuated plaque detected by intravascular ultrasound: clinical, angiographic, and morphologic features and post-percutaneous coronary intervention complications in patients with acute coronary syndromes Patterns of calcification in coronary artery disease. A statistical analysis of intravascular ultrasound and coronary angiography in 1155 lesions Impact of the Use of Intravascular Imaging on Patients Who Underwent Orbital Atherectomy Intravascular ultrasound-guided drug-eluting stent implantation: An updated meta-analysis of randomized control trials and observational studies Usefulness of intravascular ultrasound guidance in percutaneous coronary intervention with second-generation drug-eluting stents for chronic total occlusions (from the Multicenter Korean-Chronic Total Occlusion Registry) The role of integrated backscatter intravascular ultrasound in characterizing bare metal and drug-eluting stent restenotic neointima as compared to optical coherence tomography Temporal Trends in Inpatient Use of Intravascular Imaging Among Patients Undergoing Percutaneous Coronary Intervention in the United States

Original Research2018 Nov 15;271:42-48.

JOURNAL:Int J Cardiol. Article Link

Safety of intermediate left main stenosis revascularization deferral based on fractional flow reserve and intravascular ultrasound: A systematic review and meta-regression including 908 deferred left main stenosis from 12 studies

Cerrato E, Echavarria-Pinto M, D'Ascenzo F et al. Keywords: Fractional flow reserve; Intravascular ultrasound imaging; Left main intermediate stenosis

ABSTRACT


BACKGROUND - Current guidelines recommend intravascular ultrasound (IVUS) or fractional flow reserve (FFR) to decide upon ambiguous left main (LM) disease. However, no study has compared the safety of LM revascularization deferral based on FFR or IVUS.


METHODS - MEDLINE/PubMed was systematically screened for studies reporting on deferred treatment of angiographically ambiguous LM based upon FFR or IVUS evaluation. Baseline, angiographic and outcome data were appraised and pooled separately for each strategy according to random-effect models with inverse-variance weighting.


RESULTS - A total of 908 LM stenoses from 7 FFR and 5 IVUS studies were included with median follow-up of 29.0 and 31.5 months respectively. Per year of follow-up occurrence of overall MACE were 5.1% in FFR group and 6.4% in IVUS group while death, myocardial infarction, LM revascularization were respectively 2.6%, 1.5% and 1.8% vs. 3.0%, 0.5% and 2.2%. Meta-regression analysis suggested the influence of a distal LM stenosis on MACE in FFR group (β = 0.06, p = 0.01) and age in IVUS group (β = 0.4, p = 0.001). In individual studies several independent predictors of MACE were identified including use of lower doses of intracoronary adenosine (OR 1.39, p = 0.04) in FFR group and plaque burden (OR 1.34, p = 0.025), number of other diseased vessels (OR 1.39, p = 0.04) and any untreated stenosis (OR 3.80; p = 0.037) in IVUS- studies.


CONCLUSIONS - Deferring LM intermediate stenosis on the basis of FFR or IVUS showed an acceptable and similar risk of events in a mid-term follow-up. Conversely, several different variables related to each technique showed an interaction on outcome.