CBS 2019
CBSMD教育中心
中 文

IVUS Guidance

Abstract

Recommended Article

Intravascular ultrasound-guided systematic two-stent techniques for coronary bifurcation lesions and reduced late stent thrombosis Mechanisms of in-stent restenosis after drug-eluting stent implantation: intravascular ultrasound analysis The relationship between attenuated plaque identified by intravascular ultrasound and no-reflow after stenting in acute myocardial infarction: the HORIZONS-AMI (Harmonizing Outcomes With Revascularization and Stents in Acute Myocardial Infarction) trial Intravascular ultrasound assessment of the effects of rotational atherectomy in calcified coronary artery lesions A volumetric intravascular ultrasound comparison of early drug-eluting stent thrombosis versus restenosis Impact of plaque components on no-reflow phenomenon after stent deployment in patients with acute coronary syndrome: a virtual histology-intravascular ultrasound analysis Intravascular ultrasound predictors for edge restenosis after newer generation drug-eluting stent implantation Mechanical complications of everolimus-eluting stents associated with adverse events: an intravascular ultrasound study

Review Article2017 Apr;110(4):259-272

JOURNAL:Arch Cardiovasc Dis. Article Link

Contemporary use of drug-coated balloons in coronary artery disease: Where are we now?

Picard F, Doucet S, Asgar AW Keywords: Angioplastie percutanée; Athérosclérose; Ballon médicamenté; Drug-coated balloon; Drug-eluting balloon; In-stent restenosis; Paclitaxel; Percutaneous coronary intervention; Resténose intra-stent

ABSTRACT

The drug-coated balloon (DCB) has emerged as an additional tool in the arsenal of interventional cardiology devices; it delivers antiproliferative drugs to local arterial tissue by single prolonged coated balloon angioplasty inflation, and prevents restenosis, leaving no implant behind. This strategy theoretically decreases the risk of late inflammatory response to device components, without preventing positive remodelling. DCBs, when used carefully and with a good technique, may have a role in the treatment of lesion subsets, such as in-stent restenosis, small vessel disease or side branch bifurcations, in which the implantation of a drug-eluting stent is not desirable or is technically challenging. Using the latest evidence regarding the effectiveness of the currently available DCBs, this review will discuss the rationale for DCB use, and the effectiveness of DCBs in different clinical and lesion settings, and will give practical tips for their correct use in everyday clinical practice.