IVUS Guidance

Abstract

Recommended Article

Intracoronary stenting without anticoagulation accomplished with intravascular ultrasound guidance Usefulness of minimum stent cross sectional area as a predictor of angiographic restenosis after primary percutaneous coronary intervention in acute myocardial infarction (from the HORIZONS-AMI Trial IVUS substudy) Prospective application of pre-defined intravascular ultrasound criteria for assessment of intermediate left main coronary artery lesions results from the multicenter LITRO study Intravascular ultrasound findings of early stent thrombosis after primary percutaneous intervention in acute myocardial infarction: a Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction (HORIZONS-AMI) substudy Coronary artery imaging with intravascular high-frequency ultrasound Intravascular Ultrasound Guidance Reduces Cardiac Death and Coronary Revascularization in Patients Undergoing Drug-Eluting Stent Implantation: Results From a Meta-Analysis of 9 Randomized Trials and 4724 Patients Clinical impact of intravascular ultrasound guidance in drug-eluting stent implantation for unprotected left main coronary disease: pooled analysis at the patient-level of 4 registries Intravascular ultrasound guidance improves clinical outcomes during implantation of both first- and second-generation drug-eluting stents: a meta-analysis

Expert Opinion2019 Feb 16. [Epub ahead of print]

JOURNAL:J Am Coll Cardiol. Article Link

Recommendations for Institutions Transitioning to High-Sensitivity Troponin Testing JACC Scientific Expert Panel

Januzzi JL Jr, Mahler SA, Christenson RH et al. Keywords: laboratory testing; myocardial infarction; troponin

ABSTRACT


High-sensitivity cardiac troponin (hs-cTn) I or T methods have been in use in certain regions for years but are now increasingly globally adopted, including in the United States. Accordingly, inevitable challenges are created for institutions transitioning from conventional cardiac troponin (cTn) assays. hs-cTn assays have higher analytic precision at lower concentrations, yielding greater clinical sensitivity for myocardial injury and allowing accurate recognition of small changes in troponin concentration (rise or fall) within a short time frame. Although much of the knowledge regarding troponin biology that was applicable with older troponin assays still holds true, considerable education regarding the differences between conventional cTn and hs-cTn is needed before medical systems convert to the newer methods. This includes a basic understanding of how hs-cTn testing differs from conventional cTn testing and how it is best deployed in different settings, such as the emergency department and inpatient services. This Expert Panel will review important concepts for institutional transition to hs-cTn methodology, providing recommendations useful for education before implementation.


Copyright ? 2019 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.