CBS 2019
CBSMD教育中心
中 文

左主干支架

Abstract

Recommended Article

Operator Experience and Outcomes After Left Main Percutaneous Coronary Intervention Percutaneous Coronary Intervention vs Coronary Artery Bypass Grafting in Patients With Left Main Coronary Artery Stenosis: A Systematic Review and Meta-analysis Impact of Lesion Preparation Strategies on Outcomes of Left Main PCI: The EXCEL Trial Sex differences in left main coronary artery stenting: Different characteristics but similar outcomes for women compared with men Quality of Life after Everolimus-Eluting Stents or Bypass Surgery for Treatment of Left Main Disease Successful bailout stenting strategy against lethal coronary dissection involving left main bifurcation Provisional versus elective two-stent strategy for unprotected true left main bifurcation lesions: Insights from a FAILS-2 sub-study Revascularization in Patients With Left Main Coronary Artery Disease and Left Ventricular Dysfunction

Clinical Trial2017 Oct 20;13(8):962-969

JOURNAL:EuroIntervention. Article Link

Changes in high-sensitivity troponin after drug-coated balloon angioplasty for drug-eluting stent restenosis

Colleran R, Harada Y, Kufner S et al. Keywords: drug-eluting stent; biochemical markers; drug-eluting balloon

ABSTRACT


AIMS - The success of drug-coated balloon therapy might be compromised by intraprocedural particulate embolisation of matrix coating, which may cause downstream microvascular obstruction. We aimed to investigate whether drug-coated balloon therapy was associated with an increase in markers of myocardial necrosis compared with drug-eluting stents or plain balloon angioplasty.


METHODS AND RESULTS - In the ISAR-DESIRE-3 trial, patients with limus-eluting stent restenosis were randomised to treatment with a paclitaxel-coated balloon (PCB), paclitaxel-eluting stent (PES) or balloonangioplasty. We included enrolled patients who had pre- and post-intervention high-sensitivity troponin (hs-TnT) levels available. The delta (peak post-procedure minus baseline) troponin was compared between treatment arms. The association between delta troponin tertiles and three-year mortality was also evaluated. Three hundred and forty-three (343) patients were included, comprising patients treated with PCB (n=115), PES (n=112) and balloon angioplasty (n=116). Groups were well matched in terms of baseline characteristics. There was no difference in delta troponin in patients treated with PCB, PES and balloon angioplasty (36±65, 70±183, and 51±124 ng/L, respectively, p=0.16). Three-year mortality was 7.7%, 8.8% and 14.3% for the 1st, 2nd and 3rd tertiles of delta troponin, respectively, p=0.23.


CONCLUSIONS - In patients with drug-eluting stent restenosis, there was no difference in subclinical myocardial necrosis among patients treated with PCB, PES, and balloon angioplasty.