CBS 2019
CBSMD教育中心
中 文

左主干支架

Abstract

Recommended Article

Stent fracture is associated with a higher mortality in patients with type-2 diabetes treated by implantation of a second-generation drug-eluting stent Contemporary Approach to Coronary Bifurcation Lesion Treatment Left Main Stenting: What We Have Learnt So Far? Five-Year Outcomes after PCI or CABG for Left Main Coronary Disease 2-year outcomes with the Absorb bioresorbable scaffold for treatment of coronary artery disease: a systematic review and meta-analysis of seven randomised trials with an individual patient data substudy The Current State of Left Main Percutaneous Coronary Intervention Impact of different final optimization techniques on long-term clinical outcomes of left main cross-over stenting Coronary artery bypass graft surgery versus percutaneous coronary intervention in patients with three-vessel disease and left main coronary disease: 5-year follow-up of the randomised, clinical SYNTAX trial

Review ArticleVolume 69, Issue 25, June 20, Pages 3055-3066

JOURNAL:J Am Coll Cardiol. Article Link

Everolimus-Eluting Bioresorbable Scaffolds Versus Everolimus-Eluting Metallic Stents

S Sorrentino , G Giustino, GD Dangas et al Keywords: bioresorbable vascular scaffold; everolimus-eluting

ABSTRACT



Background - Recent evidence suggests that bioresorbable vascular scaffolds (BVS) are associated with an excess of thrombotic complications compared with metallic everolimus-eluting stents (EES).


Objectives - This study sought to investigate the comparative effectiveness of the Food and Drug Administration-approved BVS versus metallic EES in patients undergoing percutaneous coronary intervention at longest available follow-up.


Methods - The authors searched MEDLINE, Scopus, and web sources for randomized trials comparing BVS and EES. The primary efficacy and safety endpoints were target lesion failure and definite or probable stent thrombosis, respectively.


Results - Seven trials were included: in sum, 5,583 patients were randomized to receive either the study BVS (n = 3,261) or the EES (n = 2,322). Median time of follow-up was 2 years (range 2 to 3 years). Compared with metallic EES, risk of target lesion failure (9.6% vs. 7.2%; absolute risk difference: +2.4%; risk ratio: 1.32; 95% confidence interval: 1.10 to 1.59; number needed to harm: 41; p = 0.003; I2 = 0%) and stent thrombosis (2.4% vs. 0.7%; absolute risk difference: +1.7%; risk ratio: 3.15; 95% confidence interval: 1.87 to 5.30; number needed to harm: 60; p < 0.0001; I2 = 0%) were both significantly higher with BVS. There were no significant differences in all-cause or cardiovascular mortality between groups. The increased risk for ST associated with BVS was concordant across the early (<30 days), late (30 days to 1 year), and very late (>1 year) periods (pinteraction = 0.49).


Conclusions - Compared with metallic EES, the BVS appears to be associated with both lower efficacy and higher thrombotic risk over time. (Bioresorbable vascular scaffold compare to everolimus stents in long term follow up; CRD42017059993).