CBS 2019
CBSMD教育中心
中 文

左主干支架

Abstract

Recommended Article

Intravascular ultrasound in the evaluation and treatment of left main coronary artery disease: a consensus statement from the European Bifurcation Club Optimizing outcomes during left main percutaneous coronary intervention with intravascular ultrasound and fractional flow reserve: the current state of evidence Access Site and Outcomes for Unprotected Left Main Stem Percutaneous Coronary Intervention: An Analysis of the British Cardiovascular Intervention Society Database Impact of chronic obstructive pulmonary disease on prognosis after percutaneous coronary intervention and bypass surgery for left main coronary artery disease: an analysis from the EXCEL trial Sirolimus-eluting stent implantation for unprotected left main coronary artery stenosis: comparison with bare metal stent implantation Incidence and Management of Restenosis After Treatment of Unprotected Left Main Disease With Second-Generation Drug-Eluting Stents (from Failure in Left Main Study With 2nd Generation Stents-Cardiogroup III Study) Everolimus-eluting stent implantation for unprotected left main coronary artery stenosis. The PRECOMBAT-2 (Premier of Randomized Comparison of Bypass Surgery versus Angioplasty Using Sirolimus-Eluting Stent in Patients with Left Main Coronary Artery Disease) study Long-Term Clinical Outcomes and Optimal Stent Strategy in Left Main Coronary Bifurcation Stenting

Original ResearchApril 2020 Vol 13, Issue 4

JOURNAL:Circ Cardiovasc Interv Article Link

Global Approach to High Bleeding Risk Patients With Polymer-Free Drug-Coated Coronary Stents: The LF II Study

MW Krucoff , P Urban, J-F Tanguay et al. Keywords: high bleeding risk; PCI; DCS

ABSTRACT


BACKGROUND - High bleeding risk (HBR) patients undergoing percutaneous coronary intervention have been widely excluded from randomized device registration trials. The LF study (LEADERS FREE) reported superior outcomes of HBR patients receiving 30-day dual antiplatelet therapy after percutaneous coronary intervention with a polymer-free drug-coated stent (DCS). LFII was designed to assess the reproducibility and generalizability of the benefits of DCS observed in LF to inform the US Food and Drug Administration in a device registration decision.

 

METHODS - LFII was a single-arm study using HBR inclusion/exclusion criteria and 30-day dual antiplatelet therapy after percutaneous coronary intervention with DCS, identical to LF. The 365-day rates of the primary effectiveness (clinically indicated target lesion revascularization) and safety (composite cardiac death and myocardial infarction) end points were reported using a propensity-stratified analysis compared with the LF bare metal stent arm patients as controls.

 

RESULTS - A total of 1203 LFII patients were enrolled with an average 1.7 HBR criteria per patient, including 60.7% >75 years of age, 34.1% on anticoagulants, and 14.7% with renal failure. Propensity-adjusted 365-day clinically indicated target lesion revascularization was significantly lower with DCS (7.2% versus 9.2%; hazard ratio, 0.72 [95% CI, 0.520.98]; P=0.0338 for superiority), as was the primary safety (cardiac death and myocardial infarction) composite (9.3% versus 12.4%; hazard ratio, 0.72 [95% CI, 0.550.94]; P=0.0150 for superiority). Stent thrombosis rates were 2.0% DCS and 2.2% bare metal stent. Major bleeding at 1 year occurred in 7.2% DCS patients and 7.2% bare metal stent.

 

CONCLUSIONS - LFII reproduces the results of the DCS arm of LF in an independent, predominantly North American cohort of HBR patients.