CBS 2019
CBSMD教育中心
中 文

血管内超声指导

Abstract

Recommended Article

Comparison of intravascular ultrasound versus angiography-guided drug-eluting stent implantation: a meta-analysis of one randomised trial and ten observational studies involving 19,619 patients Consensus from the 5th European Bifurcation Club meeting Intravascular ultrasound-guided vs angiography-guided drug-eluting stent implantation in complex coronary lesions: Meta-analysis of randomized trials Optical Frequency Domain Imaging Versus Intravascular Ultrasound in Percutaneous Coronary Intervention (OPINION Trial) Results From the OPINION Imaging Study Impact of plaque components on no-reflow phenomenon after stent deployment in patients with acute coronary syndrome: a virtual histology-intravascular ultrasound analysis A three-vessel virtual histology intravascular ultrasound analysis of frequency and distribution of thin-cap fibroatheromas in patients with acute coronary syndrome or stable angina pectoris Clinical impact of intravascular ultrasound guidance in drug-eluting stent implantation for unprotected left main coronary disease: pooled analysis at the patient-level of 4 registries Attenuated plaque detected by intravascular ultrasound: clinical, angiographic, and morphologic features and post-percutaneous coronary intervention complications in patients with acute coronary syndromes

Original Research25 May 2021

JOURNAL:Eurointervention. Article Link

Incidence and Standardized Definitions of Mitral Valve Leaflet Adverse Events After Transcatheter Mitral Valve Repair: the EXPAND Study

FM Asch, SH Little, GB Mackensen et al. Keywords: mitral valve leaflet adverse events; LAE; definition; MitraClip;

ABSTRACT

BACKGROUND - An independent panel of experts reviewed all investigator-reported cases of mitral valve leaflet adverse events (LAE) after MitraClipTM NTR/XTR in the EXPAND Study.


AIMS - We aimed to report the findings of the expert panel and standardize definitions for LAE.


METHODS - Standard definitions for different types of LAE were formulated and events adjudicated after detailed review by the expert panel.


RESULTS - Enrolling centers reported LAE in 35 cases, 11 leaflet injuries (9 tear, 2 perforation) and 24 single leaflet device attachment (SLDA). The panel confirmed LAE in 20 cases (2.0% incidence), 18 patients had SLDA and 4 had leaflet injury (2 cases had both SLDA and injury). Leaflet injury occurred during device implant and resulted in surgical valve replacement or death. SLDA-alone events were identified during implant (n=2), pre-discharge (7) or at 30 days of follow-up (7) and were resolved (£ 2+ residual MR) with additional clips in 75% of cases.


CONCLUSIONS - Mitral valve repair with MitraClipTM NTR/XTR is safe. The rate of LAE is lower than previously reported using older generation devices. The proposed definitions and findings will help differentiate leaflet injury from inadequate leaflet insertion and SLDA, and provide guidance to consistently diagnose LAE post MitraClipTM.