CBS 2019
CBSMD教育中心
中 文

血管内超声指导

Abstract

Recommended Article

Comparison of plaque characteristics in narrowings with ST-elevation myocardial infarction (STEMI), non-STEMI/unstable angina pectoris and stable coronary artery disease (from the ADAPT-DES IVUS Substudy) Use of IVUS guided coronary stenting with drug eluting stent: a systematic review and meta-analysis of randomized controlled clinical trials and high quality observational studies Combined use of OCT and IVUS in spontaneous coronary artery dissection Usefulness of intravascular ultrasound to predict outcomes in short-length lesions treated with drug-eluting stents Long-term outcomes with use of intravascular ultrasound for the treatment of coronary bifurcation lesions Intracoronary stenting without anticoagulation accomplished with intravascular ultrasound guidance Role of intravascular ultrasound in patients with acute myocardial infarction undergoing percutaneous coronary intervention Positive remodeling at 3 year follow up is associated with plaque-free coronary wall segment at baseline: a serial IVUS study

Original Research2017 Aug 22;70(8):942-954.

JOURNAL:J Am Coll Cardiol. Article Link

Geometry as a Confounder When Assessing Ventricular Systolic Function: Comparison Between Ejection Fraction and Strain

Stokke TM, Hasselberg NE, Remme EW et al. Keywords: left ventricular geometry; mathematical modeling; myocardial strain

ABSTRACT


BACKGROUND - Preserved left ventricular (LV) ejection fraction (EF) and reduced myocardial strain are reported in patients with hypertrophic cardiomyopathy, ischemic heart disease, diabetes mellitus, and more.


OBJECTIVES - The authors performed a combined mathematical and echocardiographic study to understand the inconsistencies between EF and strains.


METHODS - An analytical equation showing the relationship between EF and the 4 parameters, global longitudinal strain (GLS), global circumferential strain (GCS), wall thickness, and short-axis diameter, was derived from an elliptical LV model. The equation was validated by measuring the 4 parameters by echocardiography in 100 subjects with EF ranging from 16% to 72% and comparing model-predicted EF with measured EF. The effect of the different parameters on EF was explored in the model and compared with findings in the patients.


RESULTS - Calculated EF had very good agreement with measured EF (r = 0.95). The model showed that GCS contributes more than twice as much to EF than GLS. A significant reduction of GLS could be compensated by a small increase of GCS or wall thickness or reduced diameter. The model further demonstrated how EF can be maintained in ventricles with increased wall thickness or reduced diameter, despite reductions in both longitudinal and circumferential shortening. This was consistent with similar EF in 20 control subjects and 20 hypertrophic cardiomyopathy patients with increased wall thickness and reductions in both circumferential and longitudinal shortening (all p < 0.01).


CONCLUSIONS - Reduced deformation despite preserved EF can be explained through geometric factors. Due to geometric confounders, strain better reflects systolic function in patients with preserved EF.


Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.