CBS 2019
CBSMD教育中心
中 文

双重抗血小板治疗持续时间

Abstract

Recommended Article

Does Risk of Premature Discontinuation of Dual-Antiplatelet Therapy Following PCI Attenuate With Increasing Age? Impact of bleeding during dual antiplatelet therapy in patients with coronary artery disease Rivaroxaban Plus Aspirin in Patients With Vascular Disease and Renal Dysfunction: From the COMPASS Trial Benefit-risk profile of extended dual antiplatelet therapy beyond 1 year in patients with high risk of ischemic or bleeding events after PCI A prospective, randomized, open-label trial of 6-month versus 12-month dual antiplatelet therapy after drug-eluting stent implantation in ST-elevation myocardial infarction: Rationale and design of the Ticagrelor Monotherapy Versus Ticagrelor With Aspirin in Patients With ST-Segment Elevation Myocardial Infarction Antibody-Based Ticagrelor Reversal Agent in Healthy Volunteers Dual-Antiplatelet Therapy Cessation and Cardiovascular Risk in Relation to Age: Analysis From the PARIS Registry

Original Research2006 Jun;27(11):1305-10.

JOURNAL:Eur Heart J. Article Link

Intravascular ultrasound predictors of angiographic restenosis after sirolimus-eluting stent implantation

Hong MK, Mintz GS, Lee CW et al. Keywords: post-procedural final minimum stent area; IVUS; sirolimus-eluting stent; angiographic restenosis; stent length

ABSTRACT

 

AIMS - In many countries, drug-eluting stent implantation is the dominant interventional strategy. We evaluated the clinical, angiographic, procedural, and intravascular ultrasound (IVUS) predictors of angiographic restenosis after sirolimus-eluting stent (SES) implantation.

 

METHODS AND RESULTS - SES implantation was successfully performed in 550 patients with 670 native coronary lesions. Six-month follow-up angiography was performed in 449 patients (81.6%) with 543 lesions (81.1%). Clinical, angiographic, procedural, and IVUS predictors of restenosis were determined. Using multivariable logistic regression analysis, the only independent predictors of angiographic restenosis were post-procedural final minimum stent area by IVUS [odds ratio (OR)=0.586, 95% confidence interval (CI) 0.387-0.888, P=0.012] and IVUS-measured stent length (OR=1.029, 95% CI 1.002-1.056, P=0.035). Final minimum stent area by IVUS and IVUS-measured stent length that best separated restenosis from non-restenosis were 5.5 mm2 and 40 mm, respectively. Lesions with final minimum stent area<5.5 mm2 and stent length>40 mm had the highest rate of angiographic restenosis [17.7% (11/62)], P<0.001 compared with other groups.

 

CONCLUSION - Independent predictors of angiographic restenosis after SES implantation were post-procedural final minimum stent area by IVUS and IVUS-measured stent length. The angiographic restenosis rate was highest in lesions with stent area<5.5 mm2 and stent length>40 mm.