CBS 2019
CBSMD教育中心
中 文

双重抗血小板治疗持续时间

Abstract

Recommended Article

Bleeding-Related Deaths in Relation to the Duration of Dual-Antiplatelet Therapy After Coronary Stenting Mortality Following Cardiovascular and Bleeding Events Occurring Beyond 1 Year After Coronary Stenting - A Secondary Analysis of the Dual Antiplatelet Therapy (DAPT) Study Benefit of switching dual antiplatelet therapy after acute coronary syndrome: the TOPIC (timing of platelet inhibition after acute coronary syndrome) randomized study Risk of Early Adverse Events After Clopidogrel Discontinuation in Patients Undergoing Short-Term Dual Antiplatelet Therapy: An Individual Participant Data Analysis Patterns and associations between DAPT cessation and 2-year clinical outcomes in left main/proximal LAD versus other PCI: Results from the Patterns of Non-Adherence to Dual Antiplatelet Therapy in Stented Patients (PARIS) registry Dual Antithrombotic Therapy with Dabigatran after PCI in Atrial Fibrillation Low-Dose Aspirin Discontinuation and Risk of Cardiovascular Events: A Swedish Nationwide, Population-Based Cohort Study Characterization of the Average Daily Ischemic and Bleeding Risk After Primary PCI for STEMI

Original Research2015 Aug;19(16):3012-7.

JOURNAL:Eur Rev Med Pharmacol Sci. Article Link

The impact of intravascular ultrasound guidance during drug eluting stent implantation on angiographic outcomes

Yazici HU, Agamaliyev M, Aydar Y et al. Keywords: IVUS guided PCI; DES; outcome; minimal luminal diameter; net acute gain

ABSTRACT


OBJECTIVE - Major limitation for the use of stent in the treatment of coronary artery disease is development of stent restenosis. The impact of intravascular ultrasound (IVUS) guidance during drug eluting stent (DES) implantation is presently not yet well established.


PATIENTS AND METHODS - For the present study, we included 30 patients who received DES with IVUS-guided stenting (Group A) and 30 patients receiving the DES without IVUS-guided stenting (Group B). The patients were evaluated for their ninth month control angiographies and were followed during two years for the development of relevant clinical events after the DES implantations. The angiographic and clinical results were compared between the groups.


RESULTS - After the percutaneous intervention, the minimal luminal diameter and net acute gain were significantly increased in Group A in respect to Group B (3.3 ± 0.34 vs. 2.8 ± 0.33, p < 0.01). Moreover, the rate for performing post-dilatation following stent implantation was higher in Group A than in Group B (p = 0.01). By contrast, stent restenosis rates were similar between the groups (p > 0.3).


CONCLUSIONS - The present results indicate that the use of IVUS for the implantation of DES can increase the success rate of the intervention. The IVUS guidance during DES implantation can be complementary percutaneous intervention, in particularly by detecting the situations that need for post-dilatation.