CBS 2019
CBSMD教育中心
中 文

双重抗血小板治疗持续时间

Abstract

Recommended Article

Six Versus 12 Months of Dual Antiplatelet Therapy After Implantation of Biodegradable Polymer Sirolimus-Eluting Stent: Randomized Substudy of the I-LOVE-IT 2 Trial Twelve or 30 months of dual antiplatelet therapy after drug-eluting stents Major Bleeding Rates in Atrial Fibrillation Patients on Single, Dual, or Triple Antithrombotic Therapy Dual Antiplatelet Therapy Duration: Reconciling the Inconsistencies Six-month versus 12-month dual antiplatelet therapy after implantation of drug-eluting stents: the Efficacy of Xience/Promus Versus Cypher to Reduce Late Loss After Stenting (EXCELLENT) randomized, multicenter study Optimal duration of dual antiplatelet therapy after drug-eluting stent implantation: a randomized, controlled trial. Use of clopidogrel with or without aspirin in patients taking oral anticoagulant therapy and undergoing percutaneous coronary intervention: an open-label, randomised, controlled trial A new strategy for discontinuation of dual antiplatelet therapy: the RESET Trial (REal Safety and Efficacy of 3-month dual antiplatelet Therapy following Endeavor zotarolimus-eluting stent implantation)

Original ResearchVolume 13, Issue 4, February 2020

JOURNAL:JACC Cardiovasc Interv. Article Link

Diagnostic Performance of Angiogram-Derived Fractional Flow Reserve: A Pooled Analysis of 5 Prospective Cohort Studies

G Witberg, BD Bruyne, WF Fearon et al. Keywords: coronary heart disease; coronary physiology; FFR

ABSTRACT


OBJECTIVES - This study sought to assess the diagnostic performance of FFRangio (CathWorks, Kfar Saba, Israel), an angiogram-derived fractional flow reserve (FFR) technology.

 

BACKGROUND - Despite practice guidelines recommendations, the use of coronary physiologic assessment in daily practice remains low for patients undergoing coronary angiography. Angiogram-derived FFR technologies have the potential to promote the integration of physiologic assessment in daily practice.

 

METHODS -  The study performed an analysis of pooled patient- and lesion-level data from 5 prospective cohort studies that examined the diagnostic performance of FFRangio compared with the reference standard wire-based FFR.

 

RESULTS - A total of 700 lesions from 588 patients were analyzed. Mean age was 65 years, 71% were men, and 40% presented with acute coronary syndromes. Mean FFR and FFRangio were 0.81 ± 0.12 and 0.81 ± 0.11, with 31.6% and 31.4% of lesions were in the 0.75 to 0.85 range, respectively. When using a binary cutoff FFR value of 0.80, FFRangio showed a sensitivity of 91%, a specificity of 94%, and a diagnostic accuracy of 93%. The mean difference between FFR and FFRangio was 0.00 ± 0.12. The correlation coefficient between FFR and FFRangio was 0.83 (p < 0.001). The C-statistic for FFRangio was 0.95 (p < 0.001). The accuracy of FFRangio was consistent across all subgroups examined.

 

CONCLUSIONS - In the largest reported cohort examining the performance of angiogram-derived FFR technology, FFRangio showed excellent diagnostic performance, which was robust and consistent across all patient and lesion subgroups. Additional studies are needed allow FFRangio and fulfill its potential expand the implementation of functional assessment of coronary lesions in routine clinical practice.