CBS 2019
CBSMD教育中心
中 文

双重抗血小板治疗持续时间

Abstract

Recommended Article

Six Versus 12 Months of Dual Antiplatelet Therapy After Implantation of Biodegradable Polymer Sirolimus-Eluting Stent: Randomized Substudy of the I-LOVE-IT 2 Trial Twelve or 30 months of dual antiplatelet therapy after drug-eluting stents Major Bleeding Rates in Atrial Fibrillation Patients on Single, Dual, or Triple Antithrombotic Therapy Dual Antiplatelet Therapy Duration: Reconciling the Inconsistencies Six-month versus 12-month dual antiplatelet therapy after implantation of drug-eluting stents: the Efficacy of Xience/Promus Versus Cypher to Reduce Late Loss After Stenting (EXCELLENT) randomized, multicenter study Optimal duration of dual antiplatelet therapy after drug-eluting stent implantation: a randomized, controlled trial. Use of clopidogrel with or without aspirin in patients taking oral anticoagulant therapy and undergoing percutaneous coronary intervention: an open-label, randomised, controlled trial A new strategy for discontinuation of dual antiplatelet therapy: the RESET Trial (REal Safety and Efficacy of 3-month dual antiplatelet Therapy following Endeavor zotarolimus-eluting stent implantation)

Review ArticleVolume 75, Issue 9, March 2020

JOURNAL:J Am Coll Cardiol. Article Link

Survival After Coronary Revascularization With Paclitaxel-Coated Balloons

B Scheller, D Vukadinovic, R Jeger et al. Keywords: DCB; paclitaxel; PCI; survival

ABSTRACT


BACKGROUND - Drug-coated balloons (DCBs) are accepted treatment strategies for coronary in-stent restenosis and are under clinical investigation for lesions without prior stent implantation. A recently published meta-analysis suggested an increased risk of death associated with the use of paclitaxel-coated devices in the superficial femoral artery. The reasons are incompletely understood as potential underlying pathomechanisms remain elusive, and no relationship to the administered dose has been documented.

 

OBJECTIVES - The purpose of this analysis was to investigate the available data on survival after coronary intervention with paclitaxel-coated balloons from randomized controlled trials (RCTs).

 

METHODS - PubMed, Web of science, and the Cochrane library database were searched, and a meta-analysis from RCT was performed comparing DCB with non-DCB devices (such as conventional balloon angioplasty, bare-metal stents, or drug-eluting stents) for the treatment of coronary in-stent restenosis or de novo lesions. The primary outcome was all-cause death. The number of patients lost to follow-up was observed at different time points. Risk estimates are reported as risk ratios (RRs) with 95% confidence intervals (CIs).

 

RESULTS - A total of 4,590 patients enrolled in 26 RCTs published between 2006 and 2019 were analyzed. At follow-up of 6 to 12 months, no significant difference in all-cause mortality was found, however, with numerically lower rates after DCB treatment (RR: 0.74; 95% CI: 0.51 to 1.08; p = 0.116). Risk of death at 2 years (n = 1,477, 8 RCTs) was similar between the 2 groups (RR: 0.84; 95% CI: 0.51 to 1.37; p = 0.478). After 3 years of follow-up (n = 1,775, 9 RCTs), all-cause mortality was significantly lower in the DCB group when compared with control treatment (RR: 0.73; 95% CI: 0.53 to 1.00; p = 0.047) with a number needed to treat of 36 to prevent 1 death. A similar reduction was seen in cardiac mortality (RR: 0.53; 95% CI: 0.33 to 0.85; p = 0.009).

 

CONCLUSIONS - In this meta-analysis, the use of paclitaxel DCBs for treatment of coronary artery disease was not associated with increased mortality, as has been suggested for peripheral arteries. On the contrary, use of coronary paclitaxel-coated balloons was associated with a trend toward lower mortality when compared with control treatments.