Fractional Flow Reserve

Abstract

Recommended Article

Instantaneous Wave-free Ratio versus Fractional Flow Reserve to Guide PCI Prognostic Implication of Thermodilution Coronary Flow Reserve in Patients Undergoing Fractional Flow Reserve Measurement Clinical implications of three-vessel fractional flow reserve measurement in patients with coronary artery disease Functional and morphological assessment of side branch after left main coronary artery bifurcation stenting with cross-over technique Combined Assessment of Stress Myocardial Perfusion Cardiovascular Magnetic Resonance and Flow Measurement in the Coronary Sinus Improves Prediction of Functionally Significant Coronary Stenosis Determined by Fractional Flow Reserve in Multivessel Disease Experience With an On-Site Coronary Computed Tomography-Derived Fractional Flow Reserve Algorithm for the Assessment of Intermediate Coronary Stenoses Angiographic versus functional severity of coronary artery stenoses in the FAME study fractional flow reserve versus angiography in multivessel evaluation Diagnostic accuracy of instantaneous wave free-ratio in clinical practice

Clinical Trial2018 Mar 14. [Epub ahead of print]

JOURNAL:Catheter Cardiovasc Interv. Article Link

5-Year clinical follow-up of the COBRA (complex coronary bifurcation lesions: Randomized comparison of a strategy using a dedicated self-expanding biolimus A9-eluting stent vs. a culotte strategy using everolimus-eluting stents) study

Bennett J, Adriaenssens T, McCutcheon K et al. Keywords: clinical outcome; coronary bifurcation; dedicated devices

ABSTRACT

OBJECTIVES:
We evaluated healing responses with optical coherence tomography, and long-term clinical outcomes after treatment with a dedicated stent versus a conventional culotte technique.

BACKGROUND:
Dedicated bifurcation stents have been proposed as an alternative treatment for coronary bifurcation lesions. The long-term performance of dedicated stents versus conventional dual-stent techniques for the treatment of complex coronary bifurcation lesions is unknown.

METHODS:
Forty patients with true coronary bifurcation lesions were randomized to treatment with a dedicated Axxess bifurcation stent in the proximal main vessel and additional Biomatrix stents in branches versus culotte stenting using Xience stents.

RESULTS:
The percentage of uncovered struts in each bifurcation segment at 9 months (primary endpoint) was similar between groups. Five-year clinical follow-up was available for all patients and included major adverse cardiac events [MACE; a composite of cardiac death, myocardial infarction (MI) and ischemia-driven target lesion revascularization (TLR)], target-vessel (TVR) and non-target-vessel revascularization (non-TVR), non-TLR and stent thrombosis. At 5 years, in the culotte group, one patient had undergone TLR and another suffered a clinical MI, resulting in 10% MACE versus none in the Axxess group. TVR (5% vs. 10%, P = 0.54) and non-TVR (5% vs. 20%, P = 0.39) rates were similar between the Axxess and culotte groups, respectively. There was no stent thrombosis.

CONCLUSION:
Compared with culotte stenting with Xience, complex coronary bifurcation stenting using a dedicated strategy combining the Axxess and Biomatrix stents results in similar stent strut coverage at 9 months, and excellent clinical outcomes at 5 years.

© 2018 Wiley Periodicals, Inc.