CBS 2019
CBSMD教育中心
中 文

急性冠脉综合征

Abstract

Recommended Article

Phosphoproteomic Analysis of Neonatal Regenerative Myocardium Revealed Important Roles of CHK1 via Activating mTORC1/P70S6K Pathway Coronary Angiography in Patients With Out-of-Hospital Cardiac Arrest Without ST-Segment Elevation: A Systematic Review and Meta-Analysis Natural History of Spontaneous Coronary Artery Dissection With Spontaneous Angiographic Healing Post-Discharge Bleeding and Mortality Following Acute Coronary Syndromes With or Without PCI Comparison of the Preventive Efficacy of Rosuvastatin Versus Atorvastatin in Post-Contrast Acute Kidney Injury in Patients With ST-segment Elevation Myocardial Infarction Undergoing Percutaneous Coronary Intervention Clinical Characteristics and Outcomes of STEMI Patients With Cardiogenic Shock and Cardiac Arrest Prognostically relevant periprocedural myocardial injury and infarction associated with percutaneous coronary interventions: a Consensus Document of the ESC Working Group on Cellular Biology of the Heart and European Association of Percutaneous Cardiovascular Interventions (EAPCI) Prevalence and Prognosis of Unrecognized Myocardial Infarction Determined by Cardiac Magnetic Resonance in Older Adults

Original Research2018 Oct 25;82(11):2820-2828.

JOURNAL:Circ J. Article Link

Optical Coherence Tomography Predictors for Recurrent Restenosis After Paclitaxel-Coated Balloon Angioplasty for Drug-Eluting Stent Restenosis

Miura K, Tada T, Habara S et al. Keywords: In-stent restenosis; Optical coherence tomography; Paclitaxel-coated balloon

ABSTRACT


BACKGROUND - Little is known of the relationship between optical coherence tomography (OCT) findings and recurrent restenosis after paclitaxel-coated balloon (PCB) angioplasty for drug-eluting stent in-stent restenosis (DES-ISR). To identify the predictors of recurrent restenosis after PCB angioplasty, we investigated quantitative and qualitative OCT findings during PCB angioplasty for DES-ISR. Methods and Results: In all, 222 DES-ISR lesions treated by PCB angioplasty with OCT assessment and followed-up angiographically at 6 months were divided into restenotic and non-restenotic lesions on the basis of the presence or absence of restenosis at follow-up. There was a significantly higher proportion of the heterogeneous tissue pattern in restenotic than non-restenotic lesions (26.5% vs. 11.0%, respectively; P=0.02). The OCT-derived post-procedural minimal lumen and stent areas were significantly smaller in restenotic lesions, but the intima area was similar in both groups. Post-procedural stent underexpansion, defined as a stent diameter : size of the previous stent ratio <1.0, was more frequently observed in restenotic than non-restenotic lesions (33.3% vs. 17.4%, respectively; P=0.02). Multivariate analysis identified a heterogeneous tissue pattern (odds ratio [OR] 2.92; 95% confidence interval [CI] 1.32-6.47; P=0.006) and post-procedural stent underexpansion (OR 2.36; 95% CI 1.15-4.85; P=0.04) as independent predictors of recurrent restenosis.


CONCLUSIONS - The heterogeneous tissue pattern and insufficient post-procedural minimal lumen area, caused primarily by stent underexpansion, may be associated with restenosis after PCB angioplasty for DES-ISR.