CBS 2019
CBSMD教育中心
中 文

急性冠脉综合征

Abstract

Recommended Article

Management of ST-segment elevation myocardial infarction in predominantly rural central China: A retrospective observational study Quality of Care in Chinese Hospitals: Processes and Outcomes After ST-segment Elevation Myocardial Infarction Fine particulate air pollution and hospital admissions and readmissions for acute myocardial infarction in 26 Chinese cities Symptom-Onset-To-Balloon Time, ST-Segment Resolution and In-Hospital Mortality in Patients With ST-Segment Elevation Myocardial Infarction Undergoing Primary Percutaneous Coronary Intervention in China: From China Acute Myocardial Infarction Registry Comparison of hospital variation in acute myocardial infarction care and outcome between Sweden and United Kingdom: population based cohort study using nationwide clinical registries Bare metal versus drug eluting stents for ST-segment elevation myocardial infarction in the TOTAL trial Nonculprit Stenosis Evaluation Using Instantaneous Wave-Free Ratio in Patients With ST-Segment Elevation Myocardial Infarction Door to Balloon Time: Is There a Point That Is Too Short?

Review Article2018 Feb 1;252:229-233.

JOURNAL:Int J Cardiol. Article Link

Diagnostic performance of stress perfusion cardiac magnetic resonance for the detection of coronary artery disease: A systematic review and meta-analysis

Kiaos A, Tziatzios I, Karamitsos TD et al. Keywords: Cardiovascular magnetic resonance; Coronary artery disease; Diagnostic accuracy meta-analysis; Stress perfusion

ABSTRACT


INTRODUCTION - The purpose of this study was to investigate the accuracy of qualitative stress perfusion cardiac magnetic resonance (CMR) to diagnose ischemia-causing lesions according to different definitions of significant coronary artery disease (CAD), and magnetic field strength.


METHODS - We searched PubMed, Web of Science, and the Cochrane Library for studies evaluating diagnostic performance of qualitative stress perfusion CMR for diagnosis of CAD versus coronary angiography or fractionalflow reserve (FFR) from inception to 10 September 2017. We used hierarchical models to synthesize the available data.


RESULTS - Sixty-seven studies (7113 patients) met the inclusion criteria. The patient-based analysis of studies using FFR as the reference standard demonstrated a mean sensitivity of 0.90 (95% confidence interval [CI], 0.85-0.93) and a mean specificity of 0.85 (95% CI, 0.80-0.89). The patient-based analyses for detecting coronary stenosis ≥50% and coronary stenosis ≥70% at 1.5T and for detecting coronary stenosis ≥50% and coronary stenosis ≥70%, at 3T, demonstrated a mean sensitivity of 0.82 (95% CI, 0.79-0.84), 0.86 (95% CI, 0.83-0.89), 0.90 (95% CI, 0.82-0.95), and 0.91 (95% CI, 0.79-0.96), respectively; with a mean specificity of 0.75 (95% CI, 0.71-0.80), 0.77 (95% CI, 0.71-0.81), 0.79 (95% CI, 0.69-0.86), and 0.74 (95% CI, 0.59-0.85).


CONCLUSION - Qualitative stress perfusion CMR has high accuracy for the diagnosis of CAD, irrespective of the reference standard and the magnet strength. Studies using FFR as the reference standard had higher diagnostic accuracy on a patient level compared to studies using coronary angiography, with a notable difference in specificity.


Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.