High-Sensitivity Troponin and The Application of Risk Stratification Thresholds in Patients with Suspected Acute Coronary Syndrome The year in cardiovascular medicine 2020: acute coronary syndromes and intensive cardiac care Effect of a Restrictive vs Liberal Blood Transfusion Strategy on Major Cardiovascular Events Among Patients With Acute Myocardial Infarction and Anemia: The REALITY Randomized Clinical Trial The Potential Use of the Index of Microcirculatory Resistance to Guide Stratification of Patients for Adjunctive Therapy in Acute Myocardial Infarction Healed Culprit Plaques in Patients With Acute Coronary Syndromes Cardiac Troponin Composition Characterization after Non ST-Elevation Myocardial Infarction: Relation with Culprit Artery, Ischemic Time Window, and Severity of Injury Comparison in prevalence, predictors, and clinical outcome of VSR versus FWR after acute myocardial infarction: The prospective, multicenter registry MOODY trial-heart rupture analysis High-sensitivity troponin in the evaluation of patients with suspected acute coronary syndrome: a stepped-wedge, cluster-randomised controlled trial

Original Research2022 Mar, 15 (5) 511–522

JOURNAL:2022 Mar, 15 (5) 511–522 Article Link

Propensity-Matched 1-Year Outcomes Following Transcatheter Aortic Valve Replacement in Low-Risk Bicuspid and Tricuspid Patients

GM Deeb, MJ Reardon, B Ramlawi et al. Keywords: TAVR; low-risk bicuspid and tricuspid patients

ABSTRACT

OBJECTIVES - The aim of this study was to compare 1-year outcomes after transcatheter aortic valve replacement (TAVR) in low surgical risk patients with bicuspid aortic stenosis to patients with tricuspid aortic stenosis.

 

BACKGROUND - The pivotal TAVR trials excluded patients with bicuspid aortic valves. The Low Risk Bicuspid Study 30-day primary endpoint of death or disabling stroke was 1.3%.

 

METHODS - The Low Risk Bicuspid Study is a prospective, single-arm, TAVR trial that enrolled patients from 25 U.S. sites. A screening committee confirmed bicuspid anatomy and valve classification on computed tomography using the Sievers classification. Valve sizing was by annular measurements. An independent clinical events committee adjudicated all serious adverse events, and an independent core laboratory assessed all echocardiograms. The 150 patients from the Low Risk Bicuspid Study were propensity matched to the TAVR patients in the randomized Evolut Low Risk Trial using the 1:1 5- to-1-digit greedy method, resulting in 145 pairs.

 

RESULTS - All-cause mortality or disabling stroke at 1 year was 1.4% in the bicuspid and 2.8% in the tricuspid group (P = 0.413). A pacemaker was implanted in 16.6% of bicuspid and 17.9% of tricuspid patients (P = 0.741). The effective orifice area was similar between groups at 1 year (2.2 ± 0.7 cm2 vs 2.3 ± 0.6 cm2, P = 0.677) as was the mean gradient (8.7 ± 3.9 mm Hg vs 8.5 ± 3.1 mm Hg, P = 0.754). Fewer patients in the bicuspid group had mild or worse paravalvular leak (21.3% vs 42.6%, P < 0.001).

 

CONCLUSIONS - There were no significant differences in clinical or forward flow hemodynamic outcomes between the propensity-matched groups at 1 year.